Motivated by altitude-induced fluctuations in oxygen partial pressure (pO2) and their impacts on PCS off-line arc motion and erosion response, this study proposes a comparative experimental approach featuring single-variable control under constant total pressure and coordinated multi-source electrical-signal observation. A reciprocating current-carrying arc-generation rig was established, in which pO2 was equivalently regulated via a constant-pressure gas substitution and mixing approach. High-speed imaging–based quantitative vision analysis was integrated with synchronized voltage–current measurements to evaluate the net effects of five O2 volumetric fraction levels (6, 11, 14, 17, and 21 vol%) under a DC supply of 120 V/25 A on arc dynamics, electrochemical processes, and contact pair erosion. Based on repeated-test results, the 14 vol% case exhibited the poorest stability (maximum fluctuation coefficient 20.306%), whereas the 17 vol% case showed the lowest current-carrying efficiency (minimum 56.070%) together with the most severe erosion damage. Moreover, with increasing pO2, the erosion morphology evolved in a staged manner, transitioning from localized central ablation accompanied by melt-related traces to adhesive wear-induced delamination, and ultimately to electrochemical oxidative wear. Overall, pO2 imposes a pronounced non-monotonic “window effect” on arc stability and erosion, providing key evidence for PCS structural optimization and risk assessment in open operating environments.
Li et al. (Fri,) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: