Key points are not available for this paper at this time.
Size-fractionated aerosol particles were collected in a hospital emergency department to test for airborne influenza virus. Using real-time polymerase chain reaction, we confirmed the presence of airborne influenza virus and found that 53% of detectable influenza virus particles were within the respirable aerosol fraction. Our results provide evidence that influenza virus may spread through the airborne route.
Blachère et al. (Fri,) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: