An AI-enhanced electrocardiography model (AIRE-HTN) predicted incident hypertension with a C index of 0.70 (95% CI 0.69-0.71) and stratified risk for cardiovascular death and heart failure.
Cohort (n=255,149)
Yes
Does an artificial intelligence-enhanced electrocardiography model (AIRE-HTN) predict incident hypertension and stratify risk for hypertension-associated adverse outcomes?
An AI-enhanced ECG model can predict incident hypertension and stratify risk for related adverse cardiovascular events beyond traditional clinical risk factors.
Effect estimate: C index 0.70 (95% CI 0.69-0.71)
Importance: Hypertension underpins significant global morbidity and mortality. Early lifestyle intervention and treatment are effective in reducing adverse outcomes. Artificial intelligence-enhanced electrocardiography (AI-ECG) has been shown to identify a broad spectrum of subclinical disease and may be useful for predicting incident hypertension. Objective: To develop an AI-ECG risk estimator (AIRE) to predict incident hypertension (AIRE-HTN) and stratify risk for hypertension-associated adverse outcomes. Design, Setting, and Participants: This was a development and external validation prognostic cohort study conducted at Beth Israel Deaconess Medical Center (BIDMC) in Boston, Massachusetts, a secondary care setting. External validation was conducted in the UK Biobank (UKB), a UK-based volunteer cohort. AIRE-HTN was trained and tested to predict incident hypertension using routinely collected ECGs from patients at BIDMC between 2014 and 2023. The algorithm was then evaluated to risk stratify patients for hypertension- associated adverse outcomes and externally validated on UKB data between 2014 and 2022 for both incident hypertension and risk stratification. Main Outcomes and Measures: AIRE-HTN, which uses a residual convolutional neural network architecture with a discrete-time survival loss function, was trained to predict incident hypertension. Results: AIRE-HTN was trained on 1 163 401 ECGs from 189 539 patients (mean SD age, 57.7 18.7 years; 98 747 female 52.1%) at BIDMC. A total of 19 423 BIDMC patients composed the test set and were evaluated for incident hypertension. From the UKB, AIRE-HTN was tested on 65 610 ECGs from same number of participants (mean SD age, 65.4 7.9 years; 33 785 female 51.5%). A total of 35 806 UKB patients were evaluated for incident hypertension. AIRE-HTN predicted incident hypertension (BIDMC: n = 6446 33% events; C index, 0.70; 95% CI, 0.69-0.71; UKB: n = 1532 4% events; C index, 0.70; 95% CI, 0.69-0.71). Performance was maintained in individuals without left ventricular hypertrophy and those with normal ECGs (C indices, 0.67-0.72). AIRE-HTN was significantly additive to existing clinical risk factors in predicting incident hypertension (continuous net reclassification index, BIDMC: 0.44; 95% CI, 0.33-0.53; UKB: 0.32; 95% CI, 0.23-0.37). In adjusted Cox models, AIRE-HTN score was an independent predictor of cardiovascular death (hazard ratio HR per standard deviation, 2.24; 95% CI, 1.67-3.00) and stratified risk for heart failure (HR, 2.60; 95% CI, 2.22-3.04), myocardial infarction (HR, 3.13; 95% CI, 2.55-3.83), ischemic stroke (HR, 1.23; 95% CI, 1.11-1.37), and chronic kidney disease (HR, 1.89; 95% CI, 1.68-2.12), beyond traditional risk factors. Conclusions and Relevance: Results suggest that AIRE-HTN, an AI-ECG model, can predict incident hypertension and identify patients at risk of hypertension-related adverse events, beyond conventional clinical risk factors.
Sau et al. (Thu,) conducted a cohort in Incident hypertension (n=255,149). Artificial intelligence-enhanced electrocardiography risk estimator (AIRE-HTN) vs. Existing clinical risk factors was evaluated on Incident hypertension (C index 0.70, 95% CI 0.69-0.71). An AI-enhanced electrocardiography model (AIRE-HTN) predicted incident hypertension with a C index of 0.70 (95% CI 0.69-0.71) and stratified risk for cardiovascular death and heart failure.