May 10, 1999Physical Review Letters599 citationsOpen Access

Visible Lasers with Subhertz Linewidths

View Full Paper
BYB.C. YoungFCFlávio C. CruzWIWayne M. Itano

Key Points

Key points are not available for this paper at this time.

Abstract

We report a visible laser with a subhertz linewidth for use in precision spectroscopy and as a local oscillator for an optical frequency standard. The laser derives its stability from a well-isolated, high-finesse, Fabry-P\'erot cavity. For a 563 nm laser beam locked to our stable cavity, we measure a linewidth of 0. 6 Hz for averaging times up to 32 s. The fractional frequency instability for the light locked to the cavity is typically 310^-16 at 1 s. Both the linewidth and fractional frequency instability are approximately an order of magnitude less than previously published results for stabilized lasers.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Young et al. (1999) studied this question.

synapsesocial.com/papers/6a1d5791164c88e7165de853https://doi.org/10.1103/physrevlett.82.3799