PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
January 1, 1991Clinical and Experimental Hypertension Part A Theory and Practice249 citations

A New Method for Continuous Chronic Measurement and Recording of Blood Pressure, Heart Rate and Activity in the Rat Via Radio-telemetry

View Full Paper
BBBrian BrockwayPMPerry MillsSASilvia H. Azar

Key Points

  • To develop a reliable system for continuous chronic measurement of blood pressure and heart rate in conscious laboratory rats.
  • Developed an implantable radio-telemetry device for monitoring blood pressure, heart rate, and activity.

Structured PICO

Does an implantable radio-telemetry device accurately measure continuous blood pressure in conscious rats compared to a carotid catheter?

P
Population
Conscious laboratory rats weighing greater than 175 gm (N=44)
I
Intervention
Implantable radio-telemetry device, receiver, and computer-based data acquisition system
C
Comparator
Carotid catheter
O
Outcome
Accuracy of telemetered measurements (arterial pressure) compared to carotid cathetersurrogate

The radio-telemetry system provides accurate, continuous chronic measurements of arterial pressure in conscious rats without the stressors of conventional systems.

Abstract

Accurate continuous chronic measurements of blood pressure from conscious laboratory rats are critical to many experimental protocols but have been difficult or impossible to acquire. A system consisting of an implantable radio-telemetry device, receiver, and computer-based data acquisition system that allows such measurements to be easily obtained has been developed. This system is capable of monitoring and recording arterial pressure (waveform, systolic, diastolic, and mean), heart rate, and activity from rats weighing greater than 175 gm for periods in excess of 6 months. Chronic patency has been achieved through a patented design which includes an antithrombogenic film and a gel membrane located at the catheter tip. Validation of telemetered measurements via carotid catheter has demonstrated the accuracy to be better than +/- 5 mmHg in 85% (N = 20) tested at 3 weeks post implantation, 86% (N = 15) tested at 8 weeks, and 78% (N = 9) at 12 weeks. Incidence of loss of patency was 2.3% (N = 44). This system has a demonstrated ability to obtain accurate continuous chronic measurements of arterial pressure free of the stressors associated with conventional systems.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Brockway et al. (1991) studied this question.

synapsesocial.com/papers/6a208be415e15183b6b5800bhttps://doi.org/10.3109/10641969109042094
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1A new method for measurement of blood pressure, heart rate, and activity in the mouse by radiotelemetry2000 · 173 citations
  2. 2A self-calibrating telemetry system for measurement of ventricular pressure-volume relations in conscious, freely moving rats2004 · 26 citations
  3. 3Long-term Blood Pressure Measurement in Freely Moving Mice Using Telemetry2016 · 13 citations
  4. 4Long-term telemetric measurement of cardiovascular parameters in awake mice: a physiological genomics tool2001 · 282 citations
  5. 5Telemetric monitoring of blood pressure in freely moving mice: a preliminary study2000 · 72 citations