A practical guide for microdevice fabrication using a focused ion beam equipped with a flip-stage

View Full Paper
FBFederico BalduiniIBM Research - ZurichLLLuca LavederIBM Research - ZurichNDNathan C. DruckerIBM Research - Zurich

Key Points

  • The aim is to provide a detailed protocol for fabricating microdevices with precise control over geometry and orientation using focused ion beam technology.
  • Utilized focused ion beam lithography for mesoscopic device creation.
  • Implemented an in situ flip-stage to allow for complex 3D structure design.
  • Addressed ion-induced damage and developed strategies for mitigation.
  • Optimized electrical contact deposition for low-resistance outcomes.
  • Achieved high accuracy in defining device dimensions and shapes.
  • Successfully fabricated a range of innovative device geometries.
  • Demonstrated reproducible electrical contacts with minimized resistance.

Abstract

Electrical and thermal transport measurements are essential for investigating the electronic properties of single crystal materials. While traditional methods rely on manual contact placement directly on as-grown crystals, they offer no control over sample shape and face severe limitations in resolution and reproducibility, especially when dealing with crystals smaller than one millimeter. Focused ion beam lithography has emerged as a powerful alternative, enabling the fabrication of mesoscale devices with nanometer-scale precision, control over geometry and crystallographic orientation, deposition of electrical contacts, and fabrication of minimally invasive probes. This work presents a practical guide to microdevice fabrication using a Focused Ion Beam system equipped with an in situ flip-stage. We detail a complete protocol for sculpting complex three-dimensional structures from single crystals, leveraging the flip-stage’s rotational degrees of freedom to define device width, thickness, and shape with high accuracy. The guide addresses key challenges, such as ion-induced surface damage and redeposition, and discusses strategies for mitigation. We also describe the deposition of electrical contacts via ion beam induced deposition, optimizing contact geometry and current density to achieve low-resistance, reproducible electrical contacts. Finally, we showcase a range of fabricated devices, demonstrating how the freedom to define 3D geometries enables the creation of unconventional device shapes, supporting more incisive material characterization and device prototyping.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Balduini et al. (2026) studied this question.

synapsesocial.com/papers/6990113f2ccff479cfe57bb5https://doi.org/10.1063/5.0295819
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Enabling focused ion beam sample preparation for application in reverse tip sample scanning probe microscopy2024 · 5 citations
  2. 2Thermal Transport through Single-Molecule Junctions2019 · 99 citations
  3. 3Measuring Thermal and Thermoelectric Properties of One-Dimensional Nanostructures Using a Microfabricated Device2003 · 735 citations
  4. 4Emerging Technologies for In Situ Processing1988 · 45 citations
  5. 5TEM preparation method for site- and orientation-specific sectioning of individual anisotropic nanoparticles based on shadow-FIB geometry2011 · 18 citations