Abstract Aim Cardiogenic shock remains a significant cause of mortality despite multiple advancements in medical interventions. Veno-arterial extracorporeal membrane oxygenation (VA-ECMO) provides crucial circulatory support but also increases left ventricular (LV) afterload, potentially worsening outcomes. Effective LV unloading strategies can enhance patient survival during VA-ECMO treatment. Our aim was to evaluate the impact of LV unloading strategies, including intra-aortic balloon pump (IABP) and Impella, on outcomes such as mortality and adverse effects in patients with cardiogenic shock treated with VA-ECMO. Methods A systematic search of EMBASE and Medline was conducted from inception up to 20th August 2024. Additional sources included forward citation searches of primary references. Inclusion criteria were studies reporting mortality rates in patients undergoing VA-ECMO with and without LV unloading. Exclusion criteria included case studies, editorials, commentaries, literature reviews, studies without a control group, those not examining LV unloading, studies on non-cardiogenic shock patients, and paediatric populations. From 943 identified studies, 26 met the inclusion criteria after abstract and full text screening by two authors. Data extraction followed PRISMA guidelines with independent reviewers abstracting data and assessing study quality using the Cochrane Risk of Bias in non-randomised studies (ROBINS-I) tool. A random-effects model was used to pool data, accounting for study heterogeneity. The primary outcome was all-cause mortality, assessed at three time points: intrahospital mortality (IHM), 30-day mortality and mortality at longest available follow-up. Secondary outcomes included adverse effects such as bleeding, infection, cardiovascular events, limb ischaemia, and renal replacement therapy. Results The meta-analysis included 26 studies with a total of 22,625 patients. LV unloading strategies significantly reduced mortality compared to no unloading (RR: 0.80; 95% CI: 0.73 to 0.96). IABP (RR: 0.78; 95% CI: 0.69 to 0.89) was associated with a significant reduction of mortality compared to no unloading. All adverse effects were comparable across groups apart from significantly increased infection rates and need for renal replacement therapy in Impella patients (RR: 1.37; 95% CI: 1.07 to 1.75, and RR: 2.02; 95% CI: 1.37 to 3.00, respectively). Conclusions LV unloading strategies associated with reduced mortality in patients with cardiogenic shock treated with VA-ECMO. While adverse effects are similar across all strategies, Impella specifically is linked to higher infection rates and need for renal replacement therapy. These findings could be used to support the use of LV unloading devices in clinical practice and highlight the need for further randomised controlled trials to establish optimal device-options and management protocols.
Dar et al. (Thu,) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: