Abstract Aims To assess the cost–utility of the FreeStyle Libre flash continuous glucose monitoring (CGM) system from an Italian healthcare system perspective, when compared with self‐monitoring of blood glucose (SMBG) in people living with type 2 diabetes mellitus (T2DM) receiving basal insulin. Materials and Methods A patient‐level microsimulation model was run using Microsoft Excel for 10 000 patients over a lifetime horizon, with 3.0% discounting for costs and utilities. Inputs were based on clinical trials and real‐world evidence, with patient characteristics reflecting Italian population data. The effect of flash CGM was modelled as a persistent 0.8% reduction in glycated haemoglobin versus SMBG. Costs (€ 2023) and disutilities were applied to glucose monitoring, diabetes complications, severe hypoglycaemia, and diabetic ketoacidosis. The health outcome was measured as quality‐adjusted life‐years (QALYs). Results Direct costs were €5338 higher with flash CGM than with SMBG. Flash CGM was associated with 0.51 more QALYs than SMBG, giving an incremental cost‐effectiveness ratio (ICER) of €10 556/QALY. Scenario analysis ICERs ranged from €3825/QALY to €26 737/QALY. In probabilistic analysis, flash CGM was 100% likely to be cost effective at willingness‐to‐pay thresholds > €20 000/QALY. Conclusions From an Italian healthcare system perspective, flash CGM is cost effective compared with SMBG for people living with T2DM on basal insulin.
Prato et al. (Mon,) studied this question.