In AF patients ≤50, 1-year recurrence-free survival was 71% for RFA, 69% for PFA, and 60% for Cryo; RFA had longest procedure but shortest fluoroscopy time.
Does the energy source (pulsed field, cryoballoon, or radiofrequency) affect procedural characteristics, safety, and 1-year recurrence-free survival in patients ≤ 50 years of age undergoing first pulmonary vein isolation for atrial fibrillation?
In young patients (≤50 years) undergoing first pulmonary vein isolation, radiofrequency and pulsed field ablation showed higher 1-year recurrence-free survival compared to cryoballoon ablation, alongside significant differences in procedural times.
Tasa de eventos absoluta: 0% vs 0%
Abstract Introduction Pulmonary vein isolation (PVI) is a well-established treatment for atrial fibrillation (AF), with cryoballoon ablation (Cryo), pulsed field ablation (PFA), and radiofrequency ablation (RFA) as the primary energy sources. However, little is known about the effectiveness of the three ablation modalities in young patients with AF. Purpose This study aimed to compare the procedural characteristics, safety, and effectiveness of PFA, Cryo, and RFA in patients ≤ 50 years of age undergoing PVI. Methods Patients aged ≤ 50 years with AF undergoing their first PVI were consecutively enrolled at two tertiary referral centres and followed for 1 year after the procedure. Patients were divided into three groups according to the energy source used for PVI: Cryo, PFA, and RFA. Results A total of 355 patients (median age 46 41-49 years, 18% female) were included, of whom 95 patients (27%) underwent Cryo, 102 patients (29%) PFA, and 158 patients (44%) RFA. The median procedure duration was 63 51 – 81 min for Cryo, 67 47 – 101 min for PFA, and 94 75 – 130 min for RFA (p 0.001). Similarly, left atrial dwell time was 44 34 – 57 min for Cryo, 43 27 – 74 min for PFA, and 76 57 – 97 min for RFA (p 0.001). Fluoroscopy time was significantly shorter in the RFA group (5 3 – 8 min), compared to Cryo (14 11 – 20 min) and PFA (15 10 – 25 min, p 0.001). Overall, three complications (0.8%) occurred: one phrenic nerve injury in the Cryo group (1.1%) and two pericardial tamponades in the RFA group (1.3%). The 1-year Kaplan-Meier estimate for recurrence-free survival was 60% in the Cryo group, 69% in the PFA group, and 71% in the RFA group (pLog-rank = 0.021). Conclusion In young patients with AF undergoing PVI, there are energy source-dependent differences in procedural characteristics and effectiveness. These findings warrant further investigation in larger data sets.
Liskij et al. (Sat,) reported a other. In AF patients ≤50, 1-year recurrence-free survival was 71% for RFA, 69% for PFA, and 60% for Cryo; RFA had longest procedure but shortest fluoroscopy time.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: