Puntos clave
Bearing capacity shows significant improvements with skirted footings under inclined loading in granular soil, enhancing stability.
Testing indicates that a skirt depth of 0.5 times the footing width can maximize bearing capacity under inclined conditions.
Analysis of varying load angles and soil types reveals critical thresholds impacting load distribution and performance.
Future design guidelines may benefit from these insights, though further external validation is necessary for practical application.