A robust and cost-effective fiber-optic ultrasound sensor based on a slope-symmetric Fabry–Perot interferometer (FPI) is presented, employing dual-channel quadrature-biased heterodyne interrogation with an acousto-optic modulator (AOM). By introducing a 200 MHz frequency shift that yields an effective π/2 phase offset between the direct (unshifted) and frequency-shifted optical paths, the system ensures complementary sensitivity: when one channel operates at zero slope on the FPI transfer function (minimum sensitivity), the other resides at maximum slope, providing inherent immunity to laser wavelength drift and environmental perturbations. Experimental validation demonstrates reliable ultrasound detection across varying operating points. At quadrature extremes, one channel achieves peak amplitudes of ±2 V while the other is quiescent, whereas intermediate points enable simultaneous detection with amplitudes of ±1.5 V (AOM channel) and ±0.05–0.1 V (direct channel), accompanied by corresponding DC levels ranging from ~0.4 V to 1.6 V. The AOM channel utilizes simple envelope detection after 9.5–11.5 MHz bandpass filtering, maintaining low cost, though coherent mixing is suggested for enhanced weak-signal performance. The angle-symmetric FPI design, combined with gold-disk reflector adaptations and potential femtosecond laser micromachining, further reduces fabrication costs without sacrificing finesse or sensitivity. This quadrature-biased approach offers superior stability compared to single-channel systems, making it highly suitable for practical applications in photoacoustic imaging, nondestructive testing, and structural health monitoring.
Chu et al. (Wed,) studied this question.