In this article operational problems associated with the use of landfill biogas as an alternative fuel in cogeneration systems, with particular emphasis on micro-installations based on the Perkins 4008-30 TRS2 combustion engine are presented. Such installations are commonly used in cogeneration systems, whose importance in obtaining stable electric and thermal energy is growing, especially when taking into account the additional reduction in environmental impact through biogas combustion. Reducing emissions of biogas, which consists of approximately 60% methane and approximately 35% carbon dioxide, directly reduces emissions of a greenhouse gas (GHG) with a high global warming potential (GWP). In this study the characteristics of the landfill, the biogas purification system, the measurement system and the energy balance of the entire process, biogas production → electric energy → thermal energy, are presented and the importance of this type of installation in the context of a low-carbon economy is discussed. Attention is also drawn to the operational problems of the cogeneration system, which led to its failure, requiring comprehensive repairs of the internal combustion engine.