Three-edge bearing (TEB) tests and a crack-width-dependent load-carrying model were used to assess the combined effects of recycled glass fiber-reinforced polymer (rGFRP) short fibers and glass fiber-reinforced polymer (GFRP) bars in concrete pipes. Using the force method, a circumferential statically indeterminate ring analysis was formulated to obtain internal forces at critical sections and the neutral-axis position. Fiber distribution was simulated by means of Monte Carlo sampling, and single-filament pull-out tests were fitted to relate embedded length to pull-out force, enabling calculation of the fiber-bridging contribution at cracked sections. Ten specimen types with different bar/fiber schemes were tested under external pressure to validate the model. Predicted cracking and ultimate loads agreed with measurements, with most errors within ±20%. Adding 1% (vol.) rGFRP fibers increased the cracking load by 11.81% and the ultimate load by 0.45%. Without fibers, replacing steel bars with equal-area GFRP bars increased the cracking load by 1.35% but reduced the ultimate load by 35.45%. For all specimens, the load–maximum crack-width relation was strongly linear (R2 > 0.93). The proposed approach and dataset support engineering use of recycled GFRP materials for crack control and load-carrying design of concrete pipes.
Wang et al. (Wed,) studied this question.