Los puntos clave no están disponibles para este artículo en este momento.
High-pressure in situ X-ray computational tomography measurements of sulfide solid electrolyte were conducted to elucidate the behavior of a single particle. Chlorine in Li6PS5Cl solid electrolyte was replaced by iodine to obtain high-contrast X-ray computational tomography measurements, and the behavior of a single particle under high pressure was successfully visualized. The experimental results were statistically analyzed to extract the generalized behavior of a solid electrolyte particle. The results show that pressurization increased the contact area and sphericity of a solid electrolyte particle and suppressed the voids between and within the solid electrolyte particles, thereby enhancing ionic conductivity.
Kodama et al. (Thu,) studied this question.