PCR and LAMP assays targeting 18S rDNA gene were found particularly suitable for a rapid and accurate diagnosis of AK. LAMP assay takes 2-3 h lesser than PCR, and thus offers a rapid, highly sensitive and specific, simple and affordable diagnostic modality for patients suspected of AK, especially in resource limited settings.
Mewara et al. (Sun,) studied this question.