PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
August 21, 2007Circulation843 citationsOpen Access

Aortic Diameter ≥5.5 cm Is Not a Good Predictor of Type A Aortic Dissection

View Full Paper
LPLinda PapeTTThomas T. TsaiEIEric M. Isselbacher

Structured PICO

Is aortic diameter ≥5.5 cm a good predictor of type A aortic dissection?

P
Population
Patients with acute type A aortic dissection
I
Intervention
Aortic diameter measurement (≥5.5 cm threshold)
O
Outcome
Prediction of type A aortic dissection

Current guideline thresholds of aortic diameter ≥5.5 cm fail to identify the majority of patients who present with acute type A aortic dissection, highlighting the need for alternative risk stratification methods.

Abstract

The majority of patients with acute type A acute aortic dissection present with aortic diameters <5.5 cm and thus do not fall within current guidelines for elective aneurysm surgery. Methods other than size measurement of the ascending aorta are needed to identify patients at risk for dissection.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Pape et al. (2007) studied this question.

synapsesocial.com/papers/69d96514c7f0c3ae80a3d564https://doi.org/10.1161/circulationaha.107.702720
Ask AI
Helpful
Bookmark
Share
View Full Paper