Los puntos clave no están disponibles para este artículo en este momento.
BACKGROUND: To assess the clinical outcomes of the Visian Implantable Collamer Lens (ICL) with a central port throughout 7 years of follow-up. METHODS: Eighty-four eyes of 52 patients were evaluated over a follow-up period of 7 years after V4c ICL implantation. Uncorrected (UDVA) and corrected (CDVA) distance visual acuities, refraction, intraocular pressure (IOP), endothelial cell density (ECD) and vault were analysed. RESULTS: The mean postoperative UDVA (logMAR) was 0.04 ± 0.11, 0.13 ± 0.19 and 0.17 ± 0.23 at 1-, 5- and 7-years, respectively (P 20 mmHg or an increase higher than 5 mmHg) occurred in any case throughout the 7-year of follow-up. The loss in ECD from the preoperative baseline at the last follow-up visit was 2.6%. No intraoperative or postoperative complications or adverse events occurred during the follow-up period. CONCLUSIONS: The outcomes of this study show the long-term viability of the V4c ICL implantation as a surgical option for the correction of myopia.
Fernández-Vega-Cueto et al. (Fri,) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: