Los puntos clave no están disponibles para este artículo en este momento.
Cryogenic collection of water vapor and subsequent volumetric measurement in the laboratory were used to measure stratospheric water vapor concentrations. Also measured were the deuterium and tritium content of the water samples. The isotopic measurements provide information not only on contamination during sampling, but also on the origin or previous history of the water vapor. The stratospheric H 2 O profiles show an increase with altitude which is weak for the high latitudes and steeper around 30°N. Profiles of total hydrogen (the sum of H 2 O, CH 4 , and H 2 ) show no significant vertical gradients indicating that the H 2 O increase was essentially caused by the vertical decrease in the CH 4 mixing ratio. Isotopic measurements from one flight over Alaska indicate the same.
Pollock et al. (Mon,) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: