The oxygen intake efficiency slope (OIES) was significantly correlated with maximal oxygen consumption (r = 0.966, p < 0.0001), providing an effort-independent estimation of functional reserve.
Observational (n=17)
Does the oxygen intake efficiency slope (OIES) provide an accurate submaximal estimation of cardiorespiratory functional reserve compared to VO2max in normal volunteers?
The oxygen intake efficiency slope (OIES) is a strong, effort-independent submaximal index of cardiorespiratory functional reserve that correlates highly with VO2max.
Estimación del efecto: r = 0.966
valor p: p=<0.0001
We investigated the usefulness of the oxygen intake efficiency slope (OIES) as a submaximal measure of cardiorespiratory functional reserve. OIES was derived from the relationship between oxygen consumption (VO2; ml/min) and minute ventilation (VE; l/min) during incremental exercise, which was determined by the following equation: VO2 = a logVE + b, where "a" represents OIES, which shows the effectiveness of ventilation. Maximal oxygen consumption (VO2max) is effort-dependent. There is no standard submaximal measurement of cardiorespiratory reserve that provides generally acceptable results. Exercise tests were performed by 17 normal volunteers on an ergometer using a symptom-limited Ramp protocol. Expired gas was continuously analyzed. OIES was calculated using the first 75%, 90%, and 100% of exercise data. We also determined the following submaximal parameters: the ventilatory anaerobic threshold (VAT), the slope of the minute ventilation-carbon dioxide production relationship (VE-VCO2 slope), and the extrapolated maximal oxygen consumption (EMOC). We analyzed the relationship between OIES, other submaximal parameters and VO2max, and examined the effects of submaximal exercise on OIES. The correlation coefficient of the logarithmic curve-fitting model was 0.991 +/- 0.006. OIES and VO2max were significantly correlated (r = 0.966, p < 0.0001). The correlation between OIES and VO2max was stronger than the correlation between VO2max and VAT, the VE-VCO2 slope and EMOC. OIES values for 100% and 90% of exercise were identical; OIES for 75% of exercise was slightly lower (3%). Our results suggested that OIES may provide an objective, effort-independent estimation of cardiorespiratory functional reserve.
Baba et al. (Fri,) conducted a observational in Healthy volunteers (n=17). Oxygen intake efficiency slope (OIES) vs. Other submaximal parameters (VAT, VE-VCO2 slope, EMOC) was evaluated on Correlation between OIES and VO2max (r = 0.966, p=<0.0001). The oxygen intake efficiency slope (OIES) was significantly correlated with maximal oxygen consumption (r = 0.966, p < 0.0001), providing an effort-independent estimation of functional reserve.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: