High pulse rate response to oxygen desaturations (ΔHRoxi) was associated with a higher risk of major adverse cardiovascular events compared to midrange values in patients with obstructive sleep apnoea (HR 1.42).
Cohort (n=6,309)
Sí
Does high pulse rate response to oxygen desaturations (ΔHR oxi) predict major adverse cardiovascular events in patients with obstructive sleep apnoea?
High pulse rate response to oxygen desaturations derived from pulse oximetry is an easily accessible biomarker associated with an increased risk of major adverse cardiovascular events in patients with obstructive sleep apnoea.
Estimación del efecto: HR 1.42 (95% CI 1.18-1.71)
valor p: p=<0.001
Background Sleep apnoea-specific heart rate response (ΔHR) has been identified as a promising biomarker for stratifying cardiovascular (CV) risk and predicting positive airway pressure (PAP) benefit in obstructive sleep apnoea (OSA). However, the need for prior manual scoring of respiratory events potentially limits the accessibility and reproducibility of ΔHR. We aimed to evaluate the association of pulse rate response to oxygen desaturations automatically derived from pulse oximetry (ΔHR oxi ) with CV risk in OSA. Methods ΔHR oxi and ΔHR were measured in OSA patients from the Institut de Recherche en Santé Respiratoire Pays de la Loire Sleep Cohort (PLSC; n=5002) and the HypnoLaus cohort (n=1307). The primary outcome was major adverse CV events (MACEs), a composite of mortality, stroke and cardiac diseases. Cox regression analyses were conducted to evaluate the association of ΔHR oxi and ΔHR, categorised into low, midrange and high categories, with MACEs. Results MACEs occurred in 768 patients from PLSC and 87 patients from HypnoLaus (median follow-up 8.0 and 7.5 years, respectively). Multivariable Cox models showed that subjects with high ΔHR oxi ( versus midrange) had higher risk of MACEs in PLSC (hazard ratio (HR) 1.42, 95% CI 1.18–1.71) and HypnoLaus (HR 1.72, 95% CI 1.03–2.87). Similar findings were observed for high ΔHR. Among 2718 patients from PLSC treated with PAP, the association of PAP adherence (PAP use ≥4 h·night −1 versus non-adherent) with MACEs was modified by baseline ΔHR and ΔHR oxi (p interaction <0.05). Conclusion ΔHR oxi could constitute a reliable and easy to measure biomarker for stratifying CV risk and predicting CV benefit of PAP in OSA.
Blanchard et al. (Thu,) conducted a cohort in Obstructive sleep apnoea (n=6,309). High ΔHRoxi (pulse rate response to oxygen desaturations) vs. Midrange ΔHRoxi was evaluated on Major adverse cardiovascular events (MACEs) (HR 1.42, 95% CI 1.18-1.71, p=<0.001). High pulse rate response to oxygen desaturations (ΔHRoxi) was associated with a higher risk of major adverse cardiovascular events compared to midrange values in patients with obstructive sleep apnoea (HR 1.42).