PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
August 1, 1991Anesthesia & Analgesia32 citations

Simultaneous Comparison of Intraarterial, Oscillometric, and Finapres Monitoring During Anesthesia

View Full Paper
NPNathan L. PaceTEThomas D. East

Key Points

  • This study aims to evaluate the accuracy and precision of blood pressure measurements using three different monitoring techniques during anesthesia.
  • 30 patients underwent anesthesia and surgery, with blood pressures measured every 5 minutes using three methods: intraarterial, oscillometric, and Finapres.

Structured PICO

Do oscillometric and Finapres monitoring provide accurate and precise blood pressure measurements compared to intraarterial monitoring during anesthesia?

P
Population
30 patients undergoing anesthesia and operation (15 with normal peripheral vascular status and 15 with peripheral vascular disease, hypertension, or a heavy smoking history)
I
Intervention
Blood pressure monitoring using an oscillometric arm cuff and a Finapres finger cuff
C
Comparator
Intraarterial monitoring using a radial arterial catheter
O
Outcome
Accuracy and precision of systolic, mean, and diastolic arterial pressures recorded simultaneously every 5 minsurrogate

Both oscillometric and Finapres monitoring show small bias but lack precision compared to intraarterial monitoring during anesthesia, regardless of peripheral vascular status.

Abstract

In 30 patients (15 with normal peripheral vascular status and 15 with peripheral vascular disease, hypertension, or a heavy smoking history), systolic, mean, and diastolic arterial pressures were recorded simultaneously every 5 min using a radial arterial catheter, an oscillometric arm cuff, and a Finapres finger cuff during 1-6 h of anesthesia and operation. The average accuracy of oscillometric and Finapres pressure measurements was good. Comparisons of arterial, oscillometric, and Finapres pressures showed only a small bias in the oscillometric and Finapres pressure estimations. Finapres pressures underestimated arterial pressures by 1 mm Hg more than oscillometric pressures did. Peripheral vascular status had no effect on comparisons made between pressures measured with these two techniques. Although bias was small, precision was often lacking as shown by the large variability of the difference between individual values from the three monitors. However, the precision of Finapres pressure measurements was about the same order of magnitude as that of oscillometric measurements.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Pace et al. (1991) studied this question.

synapsesocial.com/papers/6a12c18413ab6312a8c07a68https://doi.org/10.1213/00000539-199108000-00017
Ask AI
Helpful
Bookmark
Share
View Full Paper