Noninvasive Doppler-derived maximal rate of pressure fall and time constant strongly correlated with invasive catheter-derived measurements (r=0.97 and r=0.87, respectively; both p<0.001).
Observational (n=10)
Can continuous-wave Doppler aortic regurgitation velocity curves accurately and noninvasively measure left ventricular relaxation indices compared to invasive catheterization?
Continuous-wave Doppler of aortic regurgitation provides a reliable, noninvasive method to evaluate left ventricular relaxation indices, closely approximating invasive catheter measurements.
Estimación del efecto: r = 0.97 and r = 0.87
valor p: p=<0.001
BACKGROUND: The maximal negative dP/dt max (-)dP/dt and time constant (T) are useful indices for evaluating left ventricular (LV) relaxation, but they require invasive procedures. HYPOTHESIS: The purpose of this study was to obtain max (-)dP/dt and T using the continuous-wave Doppler aortic regurgitation velocity curve (AR-CW) noninvasively. Using the Bernoulli equation, the AR-CW allows accurate determination of the pressure gradients (PG) between the aorta and the left ventricle. METHODS: In 10 patients with trivial to mild AR, the rising segment of the AR-CW reflecting LV pressure decrease was digitized with the cardiac image analysis system. Transpulmonary contrast-enhanced Doppler echocardiography was used in three patients to obtain intense velocity envelope. The PG curve and the firs derivative curve were reconstructed and the maximal point of the first derivative curve, which is consistent with max(-)dP/dt, was termed as maximal rate of pressure fall (maxRPF). As T (calculated according to the method of Weiss) can be obtained from T=Pm/max(-)dP/dt Pm: LV pressure at the phase of max(-)dP/dt, we calculated T from Pm/maxRPF (Pm=dicrotic notch pressure-4Vm2) (Vm: AR velocity at the phase of maxRPF). RESULTS: The Doppler-derived maxRPF and T (TD) approximated the catheter-derived max(-)dP/dt and T (y = 0.85x + 245, r = 0.97, p < 0.001, y = 0.79x + 4, r = 0.87, p < 0.001). In addition, dobutamine echocardiography was performed in nine patients showing increased maxRPF and decreased TD, indicating improvement of LV relaxation. CONCLUSION: These Doppler-derived new indices are sufficiently useful to evaluate LV relaxation noninvasively.
Honda et al. (1996) conducted an observational in Trivial to mild aortic regurgitation (n=10). Continuous-wave Doppler aortic regurgitation velocity curve (AR-CW) vs. Invasive catheter-derived measurements was evaluated on Correlation between Doppler-derived and catheter-derived max(-)dP/dt and T (r = 0.97 and r = 0.87, p=<0.001). Noninvasive Doppler-derived maximal rate of pressure fall and time constant strongly correlated with invasive catheter-derived measurements (r=0.97 and r=0.87, respectively; both p<0.001).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: