September 13, 2006New England Journal of Medicine564 citationsOpen Access

Sirolimus-Eluting versus Uncoated Stents in Acute Myocardial Infarction

View Full Paper
CSChristian SpauldingPHPatrick HenryETEmmanuel Teíger

Key Result

Sirolimus-eluting stents significantly reduced target-vessel failure at 1 year compared to uncoated stents in patients with acute myocardial infarction (7.3% vs. 14.3%, P=0.004).

Study Design

Type

RCT (n=712)

Blinding

Single-blind

Randomization

Randomized

Multicenter

Yes

Structured PICO

Do sirolimus-eluting stents reduce target-vessel failure compared to uncoated stents in patients with acute myocardial infarction with ST-segment elevation undergoing primary PCI?

P
Population
712 patients with acute myocardial infarction with ST-segment elevation undergoing primary percutaneous coronary intervention (PCI)
I
Intervention
Sirolimus-eluting stents
C
Comparator
Uncoated stents
O
Outcome
Target-vessel failure at 1 year after the procedure, defined as target-vessel-related death, recurrent myocardial infarction, or target-vessel revascularizationcomposite

In patients with STEMI undergoing primary PCI, sirolimus-eluting stents significantly reduced target-vessel failure at 1 year compared to uncoated stents, driven primarily by a reduction in target-vessel revascularization.

Main Result

Absolute Event Rate: 7.3% vs 14.3%

p-value: p=0.004

Abstract

BACKGROUND: Sirolimus-eluting stents reduce rates of restenosis and reintervention, as compared with uncoated stents. Data are limited regarding the safety and efficacy of such stents in primary percutaneous coronary intervention (PCI) for acute myocardial infarction with ST-segment elevation. METHODS: We performed a single-blind, multicenter, prospectively randomized trial to compare sirolimus-eluting stents with uncoated stents in primary PCI for acute myocardial infarction with ST-segment elevation. The trial included 712 patients at 48 medical centers. The primary end point was target-vessel failure at 1 year after the procedure, defined as target-vessel-related death, recurrent myocardial infarction, or target-vessel revascularization. A follow-up angiographic substudy was performed at 8 months among 174 patients from selected centers. RESULTS: The rate of the primary end point was significantly lower in the sirolimus-stent group than in the uncoated-stent group (7.3% vs. 14.3%, P=0.004). This reduction was driven by a decrease in the rate of target-vessel revascularization (5.6% and 13.4%, respectively; P<0.001). There was no significant difference between the two groups in the rate of death (2.3% and 2.2%, respectively; P=1.00), reinfarction (1.1% and 1.4%, respectively; P=1.00), or stent thrombosis (3.4% and 3.6%, respectively; P=1.00). The degree of neointimal proliferation, as assessed by the mean (+/-SD) in-stent late luminal loss, was significantly lower in the sirolimus-stent group (0.14+/-0.49 mm, vs. 0.83+/-0.52 mm in the uncoated stent group; P<0.001). CONCLUSIONS: Among selected patients with acute myocardial infarction, the use of sirolimus-eluting stents significantly reduced the rate of target-vessel revascularization at 1 year. (ClinicalTrials.gov number, NCT00232830 ClinicalTrials.gov.).

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Spaulding et al. (2006) conducted an RCT in Acute myocardial infarction with ST-segment elevation (n=712). Sirolimus-eluting stents vs. Uncoated stents was evaluated on Target-vessel failure at 1 year (target-vessel-related death, recurrent myocardial infarction, or target-vessel revascularization) (p=0.004). Sirolimus-eluting stents significantly reduced target-vessel failure at 1 year compared to uncoated stents in patients with acute myocardial infarction (7.3% vs. 14.3%, P=0.004).

synapsesocial.com/papers/6a1836948008e5848e6f87b1https://doi.org/10.1056/nejmoa062006
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Three-Year Follow-up of Sirolimus-Eluting Stents vs. Bare Metal Stents for Acute Myocardial Infarction2011 · 25 citations
  2. 2Sirolimus-Eluting Stent Implantation in ST-Elevation Acute Myocardial Infarction2003 · 115 citations
  3. 3Randomized Comparison of Sirolimus-Eluting Stent Versus Standard Stent for Percutaneous Coronary Revascularization in Diabetic Patients2005 · 367 citations
  4. 4Maintenance of Long-Term Clinical Benefit With Sirolimus-Eluting Coronary Stents2005 · 214 citations
  5. 5Effectiveness and Safety of Sirolimus-Eluting Stents in the Treatment of Restenosis After Coronary Stent Placement2005 · 94 citations