Analysis of myocardial integrated backscatter using a phase-corrected magnitude cutoff of 1.0 dB detected spontaneous reperfusion (TIMI-3 flow) with 95.7% sensitivity and 90.1% specificity.
Observational (n=104)
Does analysis of myocardial integrated backscatter predict spontaneous reperfusion (TIMI-3 flow) in patients with anterior wall acute myocardial infarction?
Myocardial integrated backscatter analysis can noninvasively and accurately detect spontaneous reperfusion (TIMI-3 flow) in the emergent stage of anterior AMI.
Estimación del efecto: 95.7% sensitivity, 90.1% specificity
BACKGROUND: Spontaneous coronary reperfusion with TIMI-3 flow is associated with favorable clinical outcomes in patients with acute myocardial infarction (AMI). We investigated the ability of analyzing cardiac cycle-dependent variation of myocardial integrated backscatter (IBS) for predicting spontaneous reperfusion in anterior AMI. METHODS AND RESULTS: We recorded IBS images on admission in 104 patients with first anterior wall AMI and subsequently performed coronary angiography and coronary intervention. We measured the cyclic variation of IBS within the infarct zone and expressed its magnitude as phase-corrected magnitude (PCM) by giving positive and negative values when it showed synchronous and asynchronous contraction, respectively. Twenty-three patients showing TIMI-3 flow at the initial coronary angiography had smaller peak creatine kinase value than 57 patients with initial TIMI-0/1 flow (864+/-961 versus 2358+/-1757 IU/L; P=0.0002) and better percent wall thickening within risk area (36.1+/-15.1%) than those with TIMI-2 (16.7+/-12.8%, P<0.0001) or TIMI-0/1 (5.1+/-11.6, P<0.0001). The patients with initial TIMI-3 had higher PCM (2.7+/-1.3 dB) than those with TIMI-2 (-0.3+/-2.2 dB, P<0.0001) or those with TIMI-0/1 (-1.1+/-2.4 dB, P<0.0001). Using PCM=1.0 dB as the cutoff point, PCM detected TIMI-3 flow with 95.7% sensitivity and 90.1% specificity. Multivariable logistic regression analysis revealed that only PCM is an independent predictor for spontaneous reperfusion among the hemodynamic, echocardiographic, and electrocardiographic variables. CONCLUSIONS: Analysis of myocardial IBS could detect spontaneous reperfusion noninvasively in the emergent stage of anterior AMI.
Iwakura et al. (Tue,) conducted a observational in Anterior wall acute myocardial infarction (n=104). Myocardial integrated backscatter (IBS) phase-corrected magnitude (PCM) vs. TIMI-0/1 or TIMI-2 flow was evaluated on Detection of TIMI-3 flow (spontaneous reperfusion) using PCM=1.0 dB cutoff (95.7% sensitivity, 90.1% specificity). Analysis of myocardial integrated backscatter using a phase-corrected magnitude cutoff of 1.0 dB detected spontaneous reperfusion (TIMI-3 flow) with 95.7% sensitivity and 90.1% specificity.