PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
August 1, 1994European Journal of Cardiovascular Prevention & Rehabilitation4 citations

Clinical Use of Ambulatory Blood Pressure Monitoring: A Critical Appraisal

View Full Paper
GPGianfranco ParatiARAntonella RavogliGMG. Mancia

Key Result

Ambulatory blood pressure monitoring quantifies 24-hour variability and avoids the white-coat effect, but widespread clinical use is limited by accuracy issues and lack of normal reference values.

Structured PICO

What is the clinical utility and limitations of ambulatory blood pressure monitoring compared to traditional clinic readings in hypertension?

P
Population
Patients with hypertension (general discussion)
I
Intervention
Ambulatory blood pressure monitoring
C
Comparator
Traditional sphygmomanometric techniques (isolated clinic readings)

While ambulatory blood pressure monitoring offers advantages over clinic readings, its widespread clinical use is currently limited by accuracy issues and lack of prognostic reference data.

Limitations

  • Limited accuracy of ambulatory monitoring in ambulant individuals
  • Lack of normal reference values for 24h blood pressure
  • Need for a longitudinal demonstration of the prognostic value of the technique

Abstract

Traditional sphygmomanometric techniques are heavily affected by the 'white-coat' effect and cannot be used to assess blood pressure variability over the 24h period. These limitations can be overcome in part using ambulatory monitoring, which (1) quantifies both the mean and the variability of blood pressure over 24h, including blood pressure fluctuations between day and night, (2) does not trigger any alerting reaction in the patient, (3) provides reproducible 24h blood pressure means and (4) allows the action of antihypertensive drugs to be assessed over 24h without interference from a placebo effect. Moreover, ambulatory blood pressure values are more closely related to the end-organ damage associated with hypertension than are isolated clinic readings. However, the limited accuracy of ambulatory monitoring in ambulant individuals, the lack of normal reference values for 24h blood pressure and the need for a longitudinal demonstration of the prognostic value of the technique do not permit the recommendation of its widespread use in clinical hypertension. Although the clinical use of ambulatory monitoring should be restricted to selected cases, there is general agreement on its usefulness in clinical pharmacology trials and in studies aimed at assessing cardiovascular regulation through the analysis of 24h blood pressure and heart rate fluctuations.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Parati et al. (1994) conducted a review in Hypertension. Ambulatory blood pressure monitoring vs. Traditional sphygmomanometric techniques was evaluated. Ambulatory blood pressure monitoring quantifies 24-hour variability and avoids the white-coat effect, but widespread clinical use is limited by accuracy issues and lack of normal reference values.