This study examines the effects of jet Reynolds number (Re) and jet hole diameter (d) on flow and heat transfer in the leading-edge full-impingement cooling channel of a gas turbine nozzle guide vanes (NGV). Experiments via transient liquid crystal and numerical simulations were conducted. Results reveal that the peak Nusselt number (Nu) initially increases and then reaches a fixed value from root to tip in the spanwise direction. The area-averaged Nu presents the descending trend of the shower-head surface, pressure surface, and suction surface. In addition, the bleeding from film holes causes significant local flow acceleration and Turbulence Kinetic Energy (TKE) enhancement of 10.69%, resulting in local heat transfer elevation. The heat transfer enhancement region on both pressure and suction surfaces is inclined towards the shower-head at a 5% span region. Increasing the jet hole diameter (d) results in a decrease in both averaged Nu and TKE on the target surface. Simultaneously, the Nu gradient increases. When d = 1.6 mm, there is a recirculation zone near the hub on the suction surface and a strong crossflow near the hub on the pressure surface. The jet flow on the target surface is bending towards the shower-head. When d = 0.8 mm, the overall heat transfer is highest. However, considering heat transfer uniformity, a jet hole diameter of d = 1.2 mm offers better application.
Li et al. (Wed,) studied this question.