June 1, 2012Journal of Endovascular Therapy58 citations

St George's Vascular Institute Protocol: An Accurate and Reproducible Methodology to Enable Comprehensive Characterization of Infrarenal Abdominal Aortic Aneurysm Morphology in Clinical and Research Applications

View Full Paper
TGT. GhatwaryAKAlan KarthikesalingamBPBenjamin O. Patterson

Key Points

Key points are not available for this paper at this time.

Abstract

PURPOSE: To define the reproducibility of a protocol for the analysis of infrarenal abdominal aortic aneurysm (AAA) morphology for clinical and research purposes. METHODS: A protocol for the comprehensive assessment of preoperative AAA morphology based on formal systematic review and expert opinion featured 114 morphological parameters (maximum and minimum diameters, cross-sectional areas, vessel lengths, volumes, angulation, and calcification and tortuosity indices) in each of 3 regions: the neck, sac, and access vessels. To validate the protocol, 4 observers measured these variables on the preoperative computed tomographic angiograms from 50 patients (45 men; mean age 75 years, range 52-89) scheduled for endovascular aneurysm repair using software for 3-dimensional image reconstruction. One observer performed repeated measurements. The intra- and interobserver variabilities were calculated for all parameters; measurement time for all 114 features was recorded. RESULTS: Aortoiliac diameter, length, volume, area, and tortuosity index measurements showed good inter/intraobserver agreement. Aortic neck and aortoiliac angle measurements displayed high intra/interobserver repeatability coefficients (28%-43% and 29%-61%, respectively). Calcification measurements had the highest variability within and between observers: 39%-65% and 44%-96%, respectively. The measurement protocol was completed in a mean 105 minutes (range 55-420). CONCLUSION: Accurate 3-dimensional analysis of AAA morphology can be performed reliably within a reasonable time. Measurements that relied on consistent anatomical landmarks were most reproducible. Assessment of angulation and calcification required a number of subjective judgments, increasing the potential for variation. Automated methods are likely to be more suitable for certain measurements.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Ghatwary et al. (2012) studied this question.

synapsesocial.com/papers/6a6d231778a11c550e07d1f9https://doi.org/10.1583/11-3731mr.1
Ask AI
Helpful
Bookmark
Share
View Full Paper