Case Study for Environment Friendly Thermal Envelope Renovation

View Full Paper
BHBrigitta HorváthABAttila BogdanZPZoltán Pásztory

Key Points

  • The aim is to explore effective renovation strategies for reducing CO2 emissions in existing buildings.
  • Implemented three renovation packages from eight developed during the REHOUSE project.
  • Applied Adaptable Dynamic Building Envelope framework incorporating Intelligent Window Systems and cellulose insulation.
  • Measured changes in thermal transmittance and annual energy savings at a late 19th-century dormitory.
  • Reduced original wall thermal transmittance from 1.32 W/m2K to 0.24 W/m2K and window thermal transmittance from 1.4 W/m2K to 0.5 W/m2K.
  • Achieved annual energy savings of 3.6 MWh from the Intelligent Window System and 16.62 MWh from integrated insulation.
  • Photovoltaic systems installed produced 36.57 MWh annually, halving the building's energy balance.

Abstract

As carbon dioxide emissions are still growing, and the building sector is highly responsible for. Because the existing building stock dominates against the newly built and the operational energy consumption is double that of the embodied energy of building materials, renovation is the key area that can reduce the CO2 emissions effectively. This study presents the implementation and results of the REHOUSE project, focusing on a Hungarian demonstration site—a late 19th-century dormitory in Budapest. There were developed eight renovation packages from which three was inmplemented in the Hugnarian demo building. The Adaptable Dynamic Building Envelope provides a framework for the outer surface of renovated buildings, allowing for the integration of Intelligent Window Systems and activated cellulose insulation. . The original wall and window thermal transmittance were reduced from 1.32 W/m2K and 1.4 W/m2K to the values of 0.24 W/m2K and 0.5 W/m2K respectively. As a result of the renovation, the Intelligent Window System saves 3.6 MWh annually, while the Adaptable Dynamic Building Envelope and its integrated insulation contribute an additional 16.62 MWh in annual energy savings. . Besides these the installed PV systems on the façade and on the roof produce 36.57 MWh energy every year. The annual energy balance of the building was reduced to half of the original. The project demonstrated the importance of renovation and the significant potential in environment protection in this way.