PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
March 1, 1982Clinical Orthopaedics and Related Research207 citations

Treatment of Intertrochanteric Fracture of the Femur Using Sliding Screw Plate Fixation

View Full Paper
GWGARY L. WOLFGANGMBMICHAEL H. BRYANTJOJAMES P. O'NEILL

Key Result

Sliding screw plate fixation for intertrochanteric femur fractures had a 38.6% serious complication rate, with mechanical complications occurring in 9% of stable and 19% of unstable fractures.

Study Design

Type

Observational (n=295)

Structured PICO

What are the complication rates and technical pitfalls associated with sliding screw plate fixation for intertrochanteric fractures of the femur?

P
Population
295 intertrochanteric fractures of the femur over a nine-year period
I
Intervention
Sliding screw sideplate device fixation
O
Outcome
Mechanical fracture complications, technical error rate, and serious complication ratesafety

Sliding screw sideplate device fixation for intertrochanteric femur fractures has a significant complication rate, emphasizing the importance of reduction, operative technique, and postoperative care.

Abstract

Sliding screw plate fixation of intertrochanteric fractures of the femur is not always a simple operation with universally excellent results. There is a need to recognize potential pitfalls of this technique by careful analysis of a large number of cases. A retrospective study of 295 intertrochanteric fractures of the femur over a nine-year period was conducted. All fractures were fixed with a sliding screw sideplate device. Mechanical fracture complications occurred in 9% of 142 stable fractures and 19% of 37 unstable fractures. Medial displacement fixation reduction lowered the complication rate of unstable fractures to 10% of 19 cases. A roentgenographic study of 179 hips identified a technical error rate of 22.9% using described criteria. Including 39 deaths, 30 fracture complications, and 45 general complications, the serious complication rate was 38.6%. The sliding screw sideplate device can provide satisfactory fixation, but success is dependent on many other factors, including reduction, operative technique and postoperative care.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

WOLFGANG et al. (1982) conducted an observational in Intertrochanteric fractures of the femur (n=295). Sliding screw plate fixation was evaluated on Serious complication rate (including deaths, fracture complications, and general complications). Sliding screw plate fixation for intertrochanteric femur fractures had a 38.6% serious complication rate, with mechanical complications occurring in 9% of stable and 19% of unstable fractures.

synapsesocial.com/papers/6a0931614c1e2db30bd26394https://doi.org/10.1097/00003086-198203000-00022
Ask AI
Helpful
Bookmark
Share
View Full Paper