January 1, 2010Circulation Cardiovascular ImagingOpen Access

Noninvasive Assessment of Murine Pulmonary Arterial Pressure

View Full Paper
Ask AI
Bookmark
Share

Why the study?

Does echocardiography accurately estimate right ventricular systolic pressure compared to right heart catheterization in murine models of pulmonary hypertension?

Population

Mice with pulmonary hypertension induced acutely by infusion of a thromboxane analogue or chronically by…

Comparison

Echocardiography to measure pulmonary… vs Simultaneous right ventricle catheterization to…

Design

Preclinical

Key result

Noninvasive echocardiographic measurement of pulmonary acceleration time to ejection time ratio strongly correlated with invasive right ventricular systolic pressure in mice (r2=-0.76, P<0.0001).

Authors

HTHélène ThibaultBKBaptiste KurtzMRMichael J. Raher

Discussion

Loading...

Member takes

Overview

Supports noninvasive RVSP estimation in murine PH models; extends preclinical validation but leaves open clinical translation.

Structured PICO

Does echocardiography accurately estimate right ventricular systolic pressure compared to right heart catheterization in murine models of pulmonary hypertension?

P
Population
Mice with pulmonary hypertension induced acutely by infusion of a thromboxane analogue (U-46619) or chronically by lung-specific overexpression of interleukin-6, and wild-type mice
I
Intervention
Echocardiography (30-MHz transducer) to measure pulmonary acceleration time (PAT) and ejection time (ET) by pulsed-wave Doppler
C
Comparator
Simultaneous right ventricle catheterization to measure right ventricular systolic pressure (RVSP)
O
Outcome
Correlation of PAT and PAT/ET with RVSPsurrogate

Main Result

Effect estimate: r2=-0.76

p-value: p=<0.0001

Echocardiography-derived pulmonary acceleration time and ejection time provide a reliable, noninvasive method to estimate right ventricular systolic pressure in murine models of pulmonary hypertension.

Cite This Study

Thibault et al. (2010) studied Pulmonary arterial hypertension (murine model). Echocardiography (pulmonary acceleration time and ejection time) vs. Right heart catheterization (invasive RVSP) was evaluated on Correlation of pulmonary acceleration time to ejection time ratio (PAT/ET) with right ventricular systolic pressure (r2=-0.76, p=<0.0001). Noninvasive echocardiographic measurement of pulmonary acceleration time to ejection time ratio strongly correlated with invasive right ventricular systolic pressure in mice (r2=-0.76, P<0.0001).

synapsesocial.com/papers/6a1556905347fbb1739f9ed1https://doi.org/10.1161/circimaging.109.887109