December 24, 2013Investigative Radiology72 citations

Image Comparative Assessment Using Iterative Reconstructions

View Full Paper
VVVarut VardhanabhutiRRRichard RiordanGMGrant Mitchell

Key Points

Key points are not available for this paper at this time.

Abstract

OBJECTIVES: The objective of this study was to compare image quality (objective and subjective parameters) and confidence in lesion detection between 3 image reconstruction algorithms in computed tomographic (CT) examinations of the abdomen/pelvis. MATERIALS AND METHODS: This prospective institutional review board-approved study included 65 patients (mean SD age, 71.3 ± 9 years; mean SD body mass index, 24.4 4.8 kg) who underwent routine CT examinations of the abdomen/pelvis followed immediately by 2 low-dose scans. Raw data sets were reconstructed by using filtered back projection (FBP), adaptive statistical iterative reconstruction (ASIR), and a model-based iterative reconstruction (MBIR). Measurements of objective noise and CT numbers were compared using repeated-measures analysis of variance. Six subjective image quality parameters were scored. Diagnostic confidence and accuracy in detection of various elementary lesions were performed. RESULTS: Objectively, mean image noise for MBIR was significantly superior at all dose levels (P < 0.001). Subjectively, standard-dose ASIR and low-dose MBIR scans were better than standard-dose FBP scan in all parameters assessed (P < 0.05). Low-dose MBIR scans were comparable with standard-dose ASIR scans in all parameters except at noise index of 70 (approximately 85% dose reduction), where, in this case, the detection of liver lesions less than 5 mm were rated inferior (P < 0.05) with diagnostic accuracy reducing to 77.4%. CONCLUSIONS: Low-dose MBIR scan shows superior objective noise reduction compared with standard-dose FBP and ASIR. Subjectively, low-dose MBIR scans at 76% dose reduction were also superior compared with standard-dose FBP and ASIR. However, at dose reductions of 85%, small liver lesions may be missed.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Vardhanabhuti et al. (2013) studied this question.

synapsesocial.com/papers/6a16a8f525571367076b5e0ehttps://doi.org/10.1097/rli.0000000000000017
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Assessment of Image Quality on Effects of Varying Tube Voltage and Automatic Tube Current Modulation With Hybrid and Pure Iterative Reconstruction Techniques in Abdominal/Pelvic CT2013 · 41 citations
  2. 2Comparison of image quality between filtered back-projection and the adaptive statistical and novel model-based iterative reconstruction techniques in abdominal CT for renal calculi2013 · 46 citations
  3. 3Effect of Patient Size on Radiation Dose for Abdominal MDCT with Automatic Tube Current Modulation: Phantom Study2008 · 114 citations
  4. 4National Council on Radiation Protection and Measurements Report Shows Substantial Medical Exposure Increase2009 · 169 citations
  5. 5Managing Radiation Use in Medical Imaging: A Multifaceted Challenge2010 · 342 citations