PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
September 30, 2009IEEE Transactions on Biomedical Engineering105 citationsOpen Access

Rolling Mechanical Imaging for Tissue Abnormality Localization During Minimally Invasive Surgery

HLHongbin LiuDNDavid P. NoonanBCBen Challacombe

Key Result

Rolling mechanical imaging using a force-sensitive wheeled probe accurately localized embedded nodules in silicone phantoms and ex vivo porcine kidneys, demonstrating superior efficiency compared to discrete uniaxial indentations.

Structured PICO

P
Population
Experimental study evaluating a novel rolling mechanical imaging technique on silicone soft tissue phantoms and ex vivo porcine kidneys.
I
Intervention
Rolling mechanical imaging (RMI) using a force-sensitive wheeled probe
O
Outcome
Localization of tissue abnormalities (stiffness distribution) and localization error compared to ground truthsurrogate

A novel rolling mechanical imaging technique using a force-sensitive wheeled probe can accurately and rapidly localize tissue abnormalities in soft tissue phantoms and ex vivo porcine organs.

Limitations

  • Constant rolling indentation depth required preregistering the soft tissue surface, which is time-consuming.
  • Tissue shift during surgery may induce inaccuracies to surface registration.
  • Presence of teeth in the wheel causes periodic perturbation on the RMI.
  • Finite width of the wheel introduces localization error along the y-axis.
  • Tissue deformation during rolling indentation introduces localization errors.

Abstract

We describe a novel approach for the localization of tissue abnormalities during minimally invasive surgery using a force-sensitive wheeled probe. The concept is to fuse the kinaesthetic information from the wheel-tissue rolling interaction into a pseudocolor rolling mechanical image (RMI) to visualize the spatial variation of stiffness within the internal tissue structure. Since tissue abnormalities are often firmer than the surrounding organ or parenchyma, a surgeon then can localize abnormalities by analyzing the image. Initially, a testing facility for validating the concept in an ex vivo setting was developed and used to investigate rolling "wheel-tissue" interaction. A silicone soft-tissue phantom with embedded hard nodules was constructed to allow for experimental comparison between an RMI and a known soft-tissue structure. Tests have also been performed on excised porcine organs to show the efficacy of the method when applied to biological soft tissues. Results indicate that the RMI technique is particularly suited to identifying the stiffness distribution within a tissue sample, as the continuous force measurement along a given rolling trajectory provides repeatable information regarding relative variations in the normal tissue response. When compared to multiple discrete uniaxial indentations, the continuous measurement approach of RMI is shown to be more sensitive and facilitates coverage of a large area in a short period of time. Furthermore, if parametric classification of tissue properties based on a uniaxial tissue indentation model is desirable, the rolling indentation probe can be easily employed as a uniaxial indenter.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Liu et al. (2009) studied Tissue abnormalities during minimally invasive surgery. Rolling Mechanical Imaging (RMI) vs. Discrete uniaxial indentation was evaluated on Localization error of embedded nodules. Rolling mechanical imaging using a force-sensitive wheeled probe accurately localized embedded nodules in silicone phantoms and ex vivo porcine kidneys, demonstrating superior efficiency compared to discrete uniaxial indentations.

synapsesocial.com/papers/6a224ac4355025a8497fc731https://doi.org/10.1109/tbme.2009.2032164
Ask AI
Helpful
Bookmark
Share
View Full Paper