PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
August 28, 2009Physiological Measurement76 citations

The effect of missing RR-interval data on heart rate variability analysis in the frequency domain

View Full Paper
KKKo Keun KimLG (South Korea)JKJung Soo KimSamsung (South Korea)YLYong Gyu LimSangji University

Key Result

Simulation of missing RR-interval data in 7,182 tachograms was used to calculate normalized errors for frequency-domain HRV parameters, though specific error values were not reported in the abstract.

Structured PICO

P
Population
7,182 tachograms of 5-minute durations from the MIT-BIH normal sinus rhythm RR-interval database used to simulate missing RR-interval data.
E
Exposure
Simulation of missing RR-interval data and application of various re-sampling (nearest-neighbour, linear, cubic spline, piecewise cubic Hermite interpolation) and spectral estimation methods
C
Comparator
Data without missing data duration
O
Outcome
Normalized errors between data with and without missing data duration for frequency-domain parameters (TF, VLF, LF, HF)surrogate

This study provides methodological insights into handling missing RR-interval data for frequency-domain heart rate variability analysis.

Abstract

In this study, optimal methods for re-sampling and spectral estimation in frequency-domain heart rate variability (HRV) analysis were investigated through a simulation using artificial RR-interval data. Nearest-neighbour, linear, cubic spline and piecewise cubic Hermite interpolation methods were considered for re-sampling and representative non-parametric, parametric, and uneven approaches were used for spectral estimation. Based on this result, the effects of missing RR-interval data on frequency-domain HRV analysis were observed through the simulation of missing data using real RR-interval tachograms. For this simulation, data including the simulated artefact section (0-100 s) were used; these data were selected randomly from the real RR data obtained from the MIT-BIH normal sinus rhythm RR-interval database. In all, 7182 tachograms of 5 min durations were used for this analysis. The analysis for certain missing data durations is performed by 100 Monte Carlo runs. TF, VLF, LF and HF were estimated as the frequency-domain parameters in each run, and the normalized errors between the data with and without the missing data duration for these parameters were calculated. Rules obtained from the results of these simulations were evaluated with real missing RR-interval data derived from a capacitive-coupled ECG during sleep.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Kim et al. (2009) studied Normal sinus rhythm (n=7,182). Missing RR-interval data vs. Complete RR-interval data was evaluated on Normalized errors for TF, VLF, LF and HF parameters. Simulation of missing RR-interval data in 7,182 tachograms was used to calculate normalized errors for frequency-domain HRV parameters, though specific error values were not reported in the abstract.

synapsesocial.com/papers/6a6f4a7ac1a24a6142db52c3https://doi.org/10.1088/0967-3334/30/10/005
Ask AI
Helpful
Bookmark
Share
View Full Paper