PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
May 1, 1999IEEE Transactions on Circuits and Systems I Fundamental Theory and Applications99 citations

Analytical technique for calculating the output harmonics of an H-bridge inverter with dead time

View Full Paper
CWC.M. WuHong Kong Polytechnic UniversityWLWing-Hong LauCity University of Hong KongHCHenry Shu-Hung ChungCity University of Hong Kong

Key Points

Key points are not available for this paper at this time.

Abstract

An analytical technique for calculating the harmonic characteristics of the output voltage of an H-bridge inverter with dead time is presented. The analysis is based on a three-dimensional (3-D) model derived for generating the pulsewidth-modulated (PWM) pulse train. By applying double Fourier analysis, a generalized and elegant mathematical function for describing the harmonic components of the output voltage is formulated. The function can be divided into two parts: an ideal part representing the PWM signal without dead time and a correction part representing the dead-time effect. The function provides detailed composition of the fundamental component, signal harmonics, carrier harmonics, and cross-modulated harmonics. The proposed technique has been verified using examples and the theoretical predictions are confirmed with the results obtained from simulations using PSpice.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Wu et al. (1999) studied this question.

synapsesocial.com/papers/6a910732b24842dac47a70d4https://doi.org/10.1109/81.762927
Ask AI
Helpful
Bookmark
Share
View Full Paper