September 17, 2025Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition0 citations

Bilateral breast gradient insert prototype for strong diffusion encoding at 3T

View Full Paper
GAGerrit ArendsUniversity Medical Center UtrechtEVEdwin VersteegUtrecht UniversityFJFeng Jia

Key Points

  • The gradient insert enables local gradient strength of up to 1.32 T/m, significantly enhancing imaging capabilities.
  • Field mapping demonstrated gradient efficiency of 2.20 mT/m/A, showcasing improved performance over traditional methods.
  • 3D-printed coils and optimized wire paths contribute to the design, marking a notable advancement in MRI technology.
  • This development may transform breast cancer screening, offering a method that does not require contrast agents.

Abstract

Motivation: Diffusion MRI can provide endogenous contrast for breast cancer screening. Gradient performance is ultimately limited by physiological constraints, namely PNS. Goal(s): To develop a high-performance bilateral local breast insert gradient with dedicated bed to enable diffusion encoding for breast cancer screening. Approach: The gradient coils' wire path was optimized to achieve maximum local gradient strength, a coil carrier was 3D-printed and wound from Litz-wire. CAD-designed mechanics were fabricated using water-jet cutting. Results: Field mapping showed gradient efficiency up to 2.20 mT/m/A, enabling a local gradient strength of up to 1.32 T/m when using an amplifier with 600A. Impact: This setup presents a first step toward a dedicated MRI system for bilateral breast cancer screening using diffusion MRI. It can offer a cost-effective alternative to current screening methods, requiring no contrast agents.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Arends et al. (2025) studied this question.

synapsesocial.com/papers/68d4597031b076d99fa5c717https://doi.org/10.58530/2025/1339
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Enhanced gradient capabilities at 7T using a three-axes plug-and-play head gradient insert.2025
  2. 2Human Gradient Breast Coil: Approach for Filter Exchange Imaging with Ultra-High Gradient Amplitude2025
  3. 3Localized Gradients in an Open Field-Cycling Low-Field MRI: First Images2025
  4. 4Prostate Diffusion-Weighted Imaging with an Inside-Out Nonlinear Gradient Coil2025
  5. 5Numerical design of transverse gradient coil with transformed magnetic gradient field over an effective imaging area2024