PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
September 30, 2025Clinical Cancer Research10 citations

Glypican-3-Targeted PET Imaging for Precise Diagnosis of Hepatocellular Carcinoma: From Bench to Bedside

View Full Paper
ZLZhaoguo LinMLMengting LiZPZhidi Pan

Key Points

  • [68Ga]Ga-XH-06 successfully visualized hepatocellular carcinoma tumors, demonstrating high imaging contrast.
  • The median maximum standardized uptake value (SUVmax) for lesions was 16.9, indicating effective radiotracer uptake.
  • Cell uptake assays and animal models confirmed the targeting ability of [68Ga]Ga-XH-06 in GPC3-positive cells.
  • Eight patients experienced no adverse events during [68Ga]Ga-XH-06 PET/MR scans, suggesting a favorable safety profile.

Abstract

This study aims to develop and evaluate a novel Glypican-3 (GPC3)-targeted single-chain variable fragment (scFv)-based PET radiotracer for noninvasive assessment of GPC3 expression and precise diagnosis of hepatocellular carcinoma (HCC) in both preclinical models and a first-in-human clinical study. The novel anti-GPC3 scFv, namely XH-06, was labeled with Gallium-68 (68Ga) to obtain 68GaGa-XH-06. Cell uptake assays, small-animal PET imaging, and biodistribution studies were performed to evaluate its targeting ability. In the first-in-human study, 8 patients with suspected HCC underwent 68GaGa-XH-06 PET/magnetic resonance imaging (PET/MR). Radiotracer uptake in tumors and normal tissues was quantified, and tumor-to-blood ratios (TBR) and tumor-to-liver ratios (TLR) were calculated. 68GaGa-XH-06 was synthesized with high radiochemical purity and exhibited specific uptake and efficient internalization in GPC3-positive cells. In subcutaneous and orthotopic animal models, 68GaGa-XH-06 effectively visualized HCC tumors. Eight patients underwent 68GaGa-XH-06 PET/MR scans and no adverse events were observed. The radiotracer successfully detected HCC lesions, including sub-centimeter tumors, with high imaging contrast. Among 7 patients with HCC, the median maximum standardized uptake value (SUVmax) of the lesions was 16.9 (range, 8.2-51.8), the median TLR was 6.2 (range, 2.8-24.7) and the median TBR was 16.6 (range, 3.0-57.6) at 2.5 h post-injection. 68GaGa-XH-06 is clinically promising for detecting GPC3-positive HCC with a favorable safety profile. Further investigation is warranted to validate the clinical value of GPC3-targeted PET imaging in HCC management.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Lin et al. (2025) studied this question.

synapsesocial.com/papers/68dc1e308a7d58c25ebb134fhttps://doi.org/10.1158/1078-0432.ccr-25-1856
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1PreclinicalEvaluation of [68Ga]Ga-CS03as a Novel GPC3-Targeted Probe for Imaging GPC3 in HepatocellularCarcinoma Models2026
  2. 2Abstract 2583: [68Ga]Ga-RYZ-GPC3: A glypican-3 targeted diagnostic radiopharmaceutical for hepatocellular carcinoma molecular imaging2024
  3. 3Abstract 2585: First in human study with a novel peptide binder to glypican-3, demonstrates high specificity as a PET imaging agent in patients with hepatocellular carcinoma2024 · 4 citations
  4. 4Development and Evaluation of an Albumin-Binding GPC3-Targeting Peptide for PET Imaging of Hepatocellular Carcinoma2026
  5. 5Diagnosis and Treatment Response Monitoring of Liver Cancer using Glypican-3-Targeted Single Domain Antibody Positron Emission Tomography2025