PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
July 18, 2024Journal of Nuclear Medicine15 citationsOpen Access

61Cu-PSMA–Targeted PET for Prostate Cancer: From Radiotracer Development to First-in-Human Imaging

View Full Paper
TBTais Basaco BernabeuRMRosalba MansiLPLuigi Del Pozzo

Key Points

Key points are not available for this paper at this time.

Abstract

The demand for PET tracers that target prostate-specific membrane antigen (PSMA) continues to increase. Meeting this demand with approved 68Ga- and 18F-labeled PSMA tracers is challenging outside of major urban centers. This is because the short physical half-life of these radionuclides makes it necessary to produce them near their sites of usage. To overcome this challenge, we propose cyclotron-produced 61Cu for labeling PSMA PET tracers. 61Cu can be produced on a large scale, and its 3.33-h half-life allows shipping over considerably longer distances than possible for 68Ga and 18F. Production of true theranostic twins using 61Cu and the β−-emitter 67Cu is also feasible. Methods: PSMA-I&T (DOTAGA-(l-y)fk(sub-KuE)) and its derivative in which the DOTAGA chelator was replaced by NODAGA (NODAGA-(l-y)fk(sub-KuE)), herein reported as DOTAGA-PSMA-I&T and NODAGA-PSMA-I&T, respectively, were labeled with 61Cu and compared with 68GaGa-DOTAGA-PSMA-I&T, 68GaGa-NODAGA-PSMA-I&T, 68GaGa-PSMA-11, and 18FPSMA-1007. In vitro (lipophilicity, affinity, cellular uptake, and distribution) and in vivo (PET/CT, biodistribution, and stability) studies were performed in LNCaP cells and xenografts. Human dosimetry estimates were calculated for 61CuCu-NODAGA-PSMA-I&T. First-in-human imaging with 61CuCu-NODAGA-PSMA-I&T was performed in a patient with metastatic prostate cancer. Results: 61CuCu-DOTAGA-PSMA-I&T and 61CuCu-NODAGA-PSMA-I&T were synthesized with radiochemical purity of more than 97%, at an apparent molar activity of 24 MBq/nmol, without purification after labeling. In vitro, natural Cu (natCu)-DOTAGA-PSMA-I&T and natCu-NODAGA-PSMA-I&T showed high affinity for PSMA (inhibitory concentration of 50%, 11.2 ± 2.3 and 9.3 ± 1.8 nM, respectively), although lower than the reference natGa-PSMA-11 (inhibitory concentration of 50%, 2.4 ± 0.4 nM). Their cellular uptake and distribution were comparable to those of 68GaGa-PSMA-11. In vivo, 61CuCu-NODAGA-PSMA-I&T showed significantly lower uptake in nontargeted tissues than 61CuCu-DOTAGA-PSMA-I&T and higher tumor uptake (14.0 ± 5.0 percentage injected activity per gram of tissue %IA/g) than 61CuCu-DOTAGA-PSMA-I&T (6.06 ± 0.25 %IA/g, P = 0.0059), 68GaGa-PSMA-11 (10.2 ± 1.5 %IA/g, P = 0.0972), and 18FPSMA-1007 (9.70 ± 2.57 %IA/g, P = 0.080) at 1 h after injection. Tumor uptake was also higher for 61CuCu-NODAGA-PSMA-I&T at 4 h after injection (10.7 ± 3.3 %IA/g) than for 61CuCu-DOTAGA-PSMA-I&T (4.88 ± 0.63 %IA/g, P = 0.0014) and 18FPSMA-1007 (6.28 ± 2.19 %IA/g, P = 0.0145). Tumor-to-nontumor ratios of 61CuCu-NODAGA-PSMA-I&T were superior to those of 61CuCu-DOTAGA-PSMA-I&T and comparable to those of 68GaGa-PSMA-11 and 18FPSMA-1007 at 1 h after injection and increased significantly between 1 and 4 h after injection in most cases. Human dosimetry estimates for 61CuCu-NODAGA-PSMA-I&T were similar to the ones reported for 18F-PSMA ligands. First-in-human imaging demonstrated multifocal osseous and hepatic metastases. Conclusion: 61CuCu-NODAGA-PSMA-I&T is a promising PSMA radiotracer that compares favorably with 68GaGa-PSMA-11 and 18FPSMA-1007, while allowing delayed imaging.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Bernabeu et al. (2024) studied this question.

synapsesocial.com/papers/68e5fc83b6db643587590ddahttps://doi.org/10.2967/jnumed.123.267126
Ask AI
Helpful
Bookmark
Share
View Full Paper