Thermal analysis of a FEL SCU cryostat

View Full Paper
YSYuko ShiroyanagiEAEthan AnlikerQHQ. Hasse

Key Points

Key points are not available for this paper at this time.

Abstract

Abstract An ANL-SLAC collaboration is working on the design of a planar superconducting undulator (SCU) demonstrator to be tested at the SLAC Free Electron Laser (FEL). The demonstrator cryostat is multi-segmented, and each segment includes an ∼1.5-m-long superconducting undulator as well as other magnetic components like a phase shifter and a beam position monitor (BPM). This LHe-based cryostat is cooled by two stage pulse tube cryocoolers (Cryomech PT425-RM). A detailed load map of the cryocooler was measured and benchmarked with the manufacturer’s load map. A thermal model of one segment of the cryostat, which includes all cooling circuits, has been created in ANSYS and analyzed using the measured cryocooler load map. This paper presents the calculated cooling power requirement and the temperatures in the cryostat.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Shiroyanagi et al. (2024) studied this question.

synapsesocial.com/papers/68e6ca75b6db643587648374https://doi.org/10.1088/1757-899x/1301/1/012045
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Cryostat Design for an FEL SCU Demonstrator2024 · 1 citations
  2. 2Thermal analysis and preliminary cooldown performance of the SCU cryostat2026
  3. 3Cryogenic Distribution System for Polish Free Electron Laser Facility2024
  4. 4Conduction cooled cryostat for small-scale superconducting radio frequency accelerator applications2024
  5. 5RF characterization of a cryogenic X-band cavity beam position monitor for superconducting undulator applications at SLAC2026