PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
March 20, 2024Proceedings Series on Health & Medical Sciences1 citationsOpen Access

Variation of b Value for Axial DWI Prostate MR Imaging in Cancer: Which b Value is Optimal?

View Full Paper
NANurul AgustinaUniversitas Islam JemberFSFani SusantoMuhammadiyah University PurwokertoHUHernastiti Sedya UtamiMuhammadiyah University Purwokerto

Key Points

Key points are not available for this paper at this time.

Abstract

Background: Diffusion Weighted Imaging (DWI) is a technique that visualizes the movement of water molecules from areas of higher to lower concentration. In DWI sequences, the b-value parameter affects the signal intensity in the images. The objective of this study is to describe the differences in anatomical image information between b-value variations of 1500s/mm2, 2000s/mm2, and 2500s/mm2 in MRI prostate case cancer and to determine the most optimal b-value. Method: This study used a pre-exeachimental approach with a 1.5T Philips MRI machine at a private hospital in South Jakarta from March to April 2023. The sample consisted of 12 Prostate MRI images with DWI sequences and different b-values. Visual grading assessment was eachformed by three radiology specialists, and the data were analyzed using the Friedman test in SPSS. Results: The results showed a significant difference in anatomical image information based on the b-value variations used, with a p-value of 0.05 (0.02). The highest mean rank was obtained from the Friedman test for the b-value of 2000s/mm2. Conclusion: The significant difference in anatomical image information occurred due to differences in signal intensity and noise levels. Prostate cancer tissues appeared more hyperintense with lower noise in images with higher b-values, and vice versa. Additionally, the b-value of 2000s/mm2 resulted in the most optimal signal intensity and noise level. In conclusion, the use of b-value variations in axial DWI images of prostate cancer Prostate MRI to differences in anatomical image information, with the most optimal image information observed at a b-value of 2000s/mm2.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Agustina et al. (2024) studied this question.

synapsesocial.com/papers/68e733b8b6db6435876aceb6https://doi.org/10.30595/pshms.v5i.965
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Bright Edge Sign on High b-Value Diffusion-Weighted Imaging as a New Imaging Biomarker to Predict Poor Prognosis in Glioma Patients: A Retrospective Pilot Study2019 · 4 citations
  2. 2Comparison of Qualitative and Quantitative Evaluation of Diffusion-Weighted MRI and Chemical-Shift Imaging in the Differentiation of Benign and Malignant Vertebral Body Fractures2012 · 72 citations
  3. 3What is the optimal b value in diffusion-weighted MR imaging to depict prostate cancer at 3T?2011 · 119 citations
  4. 4Handbook of MRI technique1994 · 129 citations
  5. 5Ultra-high b-value diffusion-weighted MRI for the detection of prostate cancer with 3-T MRI2013 · 67 citations