Greater NF-FD distance is strongly correlated with higher ablation duration (R=0.789) and energy (R=0.816), indicating more difficult VPC elimination.
Does the spatial distance between earliest activation sites identified by near-field and first-deflection annotations predict the difficulty of catheter ablation for idiopathic ventricular premature contractions?
Discrepancies between endocardial earliest activation sites identified by near-field and first-deflection annotations correlate with greater procedural complexity and difficulty during VPC ablation.
Absolute Event Rate: 0% vs 0%
Abstract Background Catheter ablation is an effective treatment for ventricular premature contractions (VPCs), but complete elimination can be challenging, particularly when the origin is deep within the endocardium. Near-field (NF) annotation primarily captures endocardial signals, focusing on local VPC activation, whereas first-deflection (FD) annotation captures a broader range of signals, including those from deeper myocardial sites. We hypothesized that VPCs originating from deep sites may show discrepancies in the earliest activation site (EAS) between NF and FD annotations. Purpose To investigate the relationship between the difficulty of VPC elimination and the spatial distance between the endocardial EASs identified using NF and FD annotations (NF-FD distance). Methods We retrospectively analyzed data from 26 patients (20 males; mean age: 58±11 years) who underwent catheter ablation for idiopathic VPCs. Ablation was targeted at the FD-identified EAS using power settings of 35–50 W for up to 3 minutes per site. Complete success was defined as the absence of VPCs post-ablation, while partial success was defined as a reduction in VPCs. Failure was defined as unchanged or increased VPCs after ablation. NF-FD distance was measured retrospectively (Figure 1). Results Ablation was completely successful in 21 cases and partially successful in 5 cases. The successful ablation sites included the left ventricular outflow tract (LVOT; n=13), right ventricular outflow tract (RVOT; n=9), and other sites (n=4). The mean NF-FD distance was 8.3±8.0 mm. The mean number of ablation points, total ablation duration, and total energy delivered were 11.8±8.0 points, 739±509 seconds, and 25,615±18,618 J, respectively. The NF-FD distance moderately correlated with the number of ablation points (R=0.664, p0.001), strongly correlated with total ablation duration (R=0.789, p0.001), and strongly correlated with total energy delivered (R=0.816, p0.001) (Figure 2). Conclusion Discrepancies between the endocardial EASs identified by NF and FD annotations may reflect greater procedural complexity and difficulty in achieving VPC elimination.
Kuroki et al. (Sat,) reported a other. Greater NF-FD distance is strongly correlated with higher ablation duration (R=0.789) and energy (R=0.816), indicating more difficult VPC elimination.