In the past few decades, X-ray astronomy satellites equipped with grating spectrometers and microcalorimeters have enabled high-resolution spectroscopic observations of astrophysical objects. The need for accurate atomic data has arose as we attempt detailed analysis of the high-resolution spectra they provide. This is because current spectral models, which heavily rely on theoretical calculations, entail non-negligible uncertainties. We employ a plasma spectroscopy device called electron beam ion trap (EBIT) to experimentally obtain precise atomic data. An EBIT with a design that allows combined operation with synchrotron radiation facilities was developed based on the Heidelberg Compact EBIT and installed at ISAS/JAXA for this purpose. We conducted a spectroscopic experiment using the JAXA-EBIT at the synchrotron radiation facility SPring-8, and successfully obtained high-resolution spectra of the Lα resonance transition of Ne-like Fe16+ ions, 3C, as well as the Kα resonance transition of He-like O6+ ions. We also measured another Ne-like Fe16+ Lα resonance transition, 3G, and constrained an upper limit of the oscillator strength ratio of 3G to 3C, using our experimental results. The experimental values obtained in this study will be applied to observational studies of astrophysical objects as a part of the plasma spectral modeling.
HIRATA et al. (Thu,) studied this question.