PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
April 30, 2026Buildings0 citationsOpen Access

Effectiveness of Seismic Isolation Technique as a Retrofit Solution in the Case of an RC Building with Corroded Reinforcement

View Full Paper
DKDeniz Birlik KayıBBBeyhan BayhanGÖGökhan Özdemir

Key Points

  • This research quantifies changes in seismic response due to seismic isolation in corroded RC buildings.
  • Identified an 8-story RC building retrofitted with seismic isolation techniques.
  • Considered four corrosion scenarios and three corrosion levels based on mass loss.
  • Conducted bidirectional nonlinear response history analyses to assess effectiveness.
  • Corrosion spatial distribution significantly amplified inter-story drift ratios.
  • Seismic isolation remains effective in protecting superstructures despite corrosion issues.

Abstract

This paper aims to quantify the change in seismic response of a reinforced concrete (RC) building retrofitted by the seismic isolation technique when reinforcement corrosion is considered. In this regard, an 8-story RC building that possesses the characteristics of the existing fixed-base building stock in Türkiye has been identified and hypothetically retrofitted with lead rubber bearings (LRBs). In the numerical models, four different corrosion scenarios to represent the spatial distribution of corrosion on the frame elements of the superstructure and three different corrosion levels considering the mass losses (5, 10 and 20%) due to corrosion are considered; the corresponding reductions in (i) the cross-sectional areas of both the longitudinal and transverse reinforcements and (ii) the mechanical properties of steel and concrete are taken into account. Code-based bidirectional nonlinear response history analyses (NRHAs) are performed by considering the nonlinearity not only in the seismic isolation system but also in the superstructure. Furthermore, LRBs are represented by a force–displacement relation that enables modeling of the deterioration in strength of isolators due to lead core heating during cyclic motion. The results revealed that the spatial distribution of the corrosion is highly effective in amplification of inter-story drift ratios (ISDRs), which can be in the order of 2-fold depending on the level of mass loss. It is found that the seismic isolation technique is still effective in protecting the superstructure against earthquakes even though there is a corrosion problem in frame members.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Kayı et al. (2026) studied this question.

synapsesocial.com/papers/69f2a4b78c0f03fd67763cf6https://doi.org/10.3390/buildings16091736
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Effect of superstructure characteristics on seismic response of an RC building retrofitted with lead rubber bearings2026
  2. 2Numerical Investigation on the Seismic Performance of a Multistorey RC Building under Increased Seismic Demand Using Lead Rubber Bearing Isolation2026
  3. 3A Comparative Experimental Study on Seismic Retrofitting Techniques for RC Frames: RC Jacketing, Steel Jacketing, and Base Isolation2025 · 2 citations
  4. 4Comparison of alternative seismic retrofitting strategies for a substandard reinforced concrete building: a cost-benefit analysis2026 · 1 citations
  5. 5Seismic Retrofitting of Existing RC Buildings: A Comprehensive Review of Methods, Analysis Techniques, and Future Directions2026