PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
January 1, 2015Applied Bionics and Biomechanics20 citationsOpen Access

Structural Design and Sealing Performance Analysis of Biomimetic Sealing Ring

View Full Paper
CHChuanjun HanHZHan ZhangJZJie Zhang

Key Points

Key points are not available for this paper at this time.

Abstract

In order to reduce the failure probability of rubber sealing rings in reciprocating dynamic seal, a new structure of sealing ring based on bionics was designed. The biomimetic ring has three concave ridges and convex bulges on each side which are very similar to earthworms. Bulges were circularly designed and sealing performances of the biomimetic ring in both static seal and dynamic seal were simulated by FEM. In addition, effects of precompression, medium pressure, speed, friction coefficient, and material parameters on sealing performances were discussed. The results show that von Mises stress of the biomimetic sealing ring distributed symmetrically in no-pressure static sealing. The maximum von Mises stress appears on the second bulge of the inner side. High contact stress concentrates on left bulges. Von Mises stress distribution becomes uneven under medium pressure. Both von Mises stress and contact stress increase when precompression, medium pressure, and rubber hardness increase in static sealing. Biomimetic ring can avoid rolling and distortion in reciprocating dynamic seal, and its working life is much longer than O-ring and rectangular ring. The maximum von Mises stress and contact stress increase with the precompression, medium pressure, rubber hardness, and friction coefficient in reciprocating dynamic seal.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Han et al. (2015) studied this question.

synapsesocial.com/papers/6a036ba6b39fea9cf39bd580https://doi.org/10.1155/2015/358417
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Effects of laser parameters on the geometrical characteristics of peg-shaped bionic coupling unit2014 · 8 citations
  2. 2Experimental and numerical investigation on drag reduction of non-smooth bionic jet surface2014 · 70 citations
  3. 3Failure analysis and finite element simulation of key components of PDM2014 · 24 citations
  4. 4Thermal failure of rubber bushing of a Positive Displacement Motor: A study based on thermo-mechanical coupling2014 · 34 citations