December 16, 2004European Journal of Heart Failure128 citations

Work-Rate Affects Cardiopulmonary Exercise Test Results in Heart Failure

View Full Paper
PAPiergiuseppe AgostoniMBMichele Leonardo BianchiAMAndrea Moraschi

Key Result

A 5-minute cardiopulmonary exercise test ramp protocol yielded a lower peak VO2 (16.9 ml/min/kg) compared to a 10-minute protocol (18.0 ml/min/kg, p<0.001) in patients with chronic heart failure.

Key Points

  • Determine whether ramp work-rate increment and exercise duration influence cardiopulmonary exercise test parameters across varying severities of chronic heart failure.
  • Enrolled 90 chronic heart failure patients stratified into three exercise capacity groups based on initial peak oxygen uptake (>20 ml/min/kg, n=28; 15-20 ml/min/kg, n=39; <15 ml/min/kg, n=23).
  • Administered three subsequent ramp exercise protocols in randomized order targeting peak exercise durations of 5, 10, and 15 minutes, with mean work-rates of 22.7 ± 8.0, 11.6 ± 3.7, and 7.5 ± 2.9 W/min.
  • Peak oxygen uptake was significantly lower in the 5-minute test (16.9 ± 4.3 ml/min/kg) compared to both the 10-minute (18.0 ± 4.4 ml/min/kg, p < 0.001) and 15-minute tests (18.0 ± 5.4 ml/min/kg).
  • The 5-minute protocol produced the lowest peak heart rate, peak ventilation, and ΔVO2/Δwork-rate slope across all heart failure severity subsets.
  • Ventilatory efficiency (VE/VCO2 slope) and oxygen uptake at the anaerobic threshold were not significantly affected by protocol duration in any heart failure group.

Study Design

Type

RCT (n=90)

Randomization

Randomized

PICO

P
Population
Chronic heart failure (HF) (n=90)
I
Intervention / Comparator
Cardiopulmonary exercise test (CPET) ramp protocols vs Comparison among 5, 10, and 15 min protocols (Work-rate increased to reach peak exercise in 5, 10, and 15 min)
O
Primary Outcome
Peak V(O2), p=<0.001

Main Result

Absolute Event Rate: 16.9% vs 18%

p-value: p=<0.001

Abstract

AIMS: Cardiopulmonary exercise test (CPET) is used to evaluate patients with chronic heart failure (HF) usually by means of a personalized ramp exercise protocol. Our aim was to evaluate if exercise duration or ramp rate influences the results. METHODS AND RESULTS: Ninety HF patients were studied (peak V (O(2)): >20 ml/min/kg, n=28, 15-20 ml/min/kg, n=39 and <15 ml/min/kg, n=23). Each patient did four CPET studies. The initial study was used to separate the subjects into three groups, according to their exercise capacity. In the remaining studies, work-rate was increased at three different rates designed to have the subjects reach peak exercise in 5, 10 and 15 min from the start of the ramp increase in work-rate, respectively. The order was randomized. The work-rate applied for the total population averaged 22.7+/-8.0, 11.6+/-3.7, 7.5+/-2.9 W/min with effective loaded exercise duration of 5 min and 16 s+/-29 s, 9 min and 43 s+/-49 s and 14 min and 32 s+/-1 min and 12 s for the 5-, 10- and 15-min tests, respectively. Peak V (O(2)) averaged 16.9+/-4.3*, 18.0+/-4.4 and 18.0+/-5.4 ml/min/kg for the 5-, 10- and 15-min tests, (*=p<0.001 vs. 10 min). The shortest test had the lowest peak heart rate and ventilation and highest peak work-rate. Peak V (O(2)) and heart rate were lowest in 5-min tests regardless of HF severity. The DeltaV (O(2))/Deltawork-rate was lowest in 5-min tests and highest in 15-min tests. At all ramp rates, DeltaV (O(2))/Deltawork-rate was lower for the subjects with the lower peak V (O(2)). The V (e)/V (CO(2)) slope and V (O(2)) at anaerobic threshold were not affected by the protocol for any grade of HF. CONCLUSIONS: In chronic HF, exercise protocol has a small effect on peak V (O(2)) and DeltaV (O(2))/Deltawork but does not affect V (O(2)) at anaerobic threshold and V (e)/V (CO(2)) slope.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Agostoni et al. (2004) conducted an RCT in Chronic heart failure (HF) (n=90). Cardiopulmonary exercise test (CPET) ramp protocols vs. Comparison among 5, 10, and 15 min protocols was evaluated on Peak V(O2) (p=<0.001). A 5-minute cardiopulmonary exercise test ramp protocol yielded a lower peak VO2 (16.9 ml/min/kg) compared to a 10-minute protocol (18.0 ml/min/kg, p<0.001) in patients with chronic heart failure.