Key points are not available for this paper at this time.
BACKGROUND: For people with localised prostate cancer, active treatments are effective but have significant side effects. Minimally invasive treatments that destroy (or ablate) either the entire gland or the part of the prostate with cancer may be as effective and cause less side effects at an acceptable cost. Such therapies include cryotherapy, high-intensity focused ultrasound (HIFU) and brachytherapy, among others. OBJECTIVES: This study aimed to determine the relative clinical effectiveness and cost-effectiveness of ablative therapies compared with radical prostatectomy (RP), external beam radiotherapy (EBRT) and active surveillance (AS) for primary treatment of localised prostate cancer, and compared with RP for salvage treatment of localised prostate cancer which has recurred after initial treatment with EBRT. DATA SOURCES: MEDLINE (1946 to March week 3, 2013), MEDLINE In-Process 14 case series, 1 RCT and 4 non-randomised comparative studies (NRCSs)], HIFU (4000 patients; 20 case series, 1 NRCS) and brachytherapy (26,129 patients; 2 RCTs, 38 NRCSs) studies provided limited data for meta-analyses. All studies were considered at high risk of bias. There was no robust evidence that mortality (4-year survival 93% for cryotherapy, 99% for HIFU, 91% for EBRT) or other cancer-specific outcomes differed between treatments. For functional and quality-of-life outcomes, the paucity of data prevented any definitive conclusions from being made, although data on incontinence rates and erectile dysfunction for all ablative procedures were generally numerically lower than for non-ablative procedures. The safety profiles were comparable with existing treatments. Studies reporting the use of focal cryotherapy suggested that incontinence rates may be better than for whole-gland treatment. Data on AS, salvage treatment and other ablative therapies were too limited. The cost-effectiveness analysis confirmed the uncertainty from the clinical review and that there is no technology which appears superior, on the basis of current evidence, in terms of average cost-effectiveness. The probabilistic sensitivity analyses suggest that a number of ablative techniques are worthy of further research. LIMITATIONS: The main limitations were the quantity and quality of the data available on cancer-related outcomes and dysfunction. CONCLUSIONS: The findings indicate that there is insufficient evidence to form any clear recommendations on the use of ablative therapies in order to influence current clinical practice. Research efforts in the use of ablative therapies in the management of prostate cancer should now be concentrated on the performance of RCTs and the generation of standardised outcomes. STUDY REGISTRATION: This study is registered as PROSPERO CRD42012002461. FUNDING: The National Institute for Health Research Health Technology Assessment programme.
Ramsay et al. (Wed,) studied this question.