PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
November 10, 1998Circulation117 citationsOpen Access

Electromechanical Characterization of Chronic Myocardial Infarction in the Canine Coronary Occlusion Model

View Full Paper
LGLior GepsteinAGAlexander GoldinJLJonathan Lessick

Key Result

Catheter-based electromechanical mapping demonstrated significantly lower endocardial local shortening in infarcted areas compared to controls (1.2% vs 15.5%, P<0.01).

Key Points

  • To define and quantify the electromechanical properties of dysfunctional myocardial tissue in chronic myocardial infarction.
  • Used a catheter-based mapping technique to assess 11 dogs with chronic infarction and 6 controls.
  • Recorded local electrograms and dynamic electromechanical data from 13 left ventricular regions during the cardiac cycle.
  • Analyzed endocardial local shortening and bipolar amplitude to evaluate the extent of infarction.
  • Endocardial local shortening was significantly lower in the infarcted area (1.2% vs. 7.2%-13.5% in noninfarcted regions, P<0.01).
  • Bipolar electrogram amplitude was significantly reduced in the infarcted zone (2.3 mV vs. 4.0-10.2 mV in noninfarcted regions, P<0.01).
  • High correlation with pathology images demonstrated accurate delineation of infarct location and size (Pearson's r=0.90).

Structured PICO

P
Population
11 dogs with chronic myocardial infarction (4 weeks after LAD ligation) and 6 control dogs
I
Intervention
Nonfluoroscopic, catheter-based electromechanical mapping
C
Comparator
Noninfarcted regions and control dogs
O
Outcome
Endocardial local shortening and intracardiac bipolar electrogram amplitudesurrogate

A nonfluoroscopic catheter-based mapping technique can accurately quantify and delineate abnormal regional mechanical and electrical functions in chronic myocardial infarction.

Main Result

Absolute Event Rate: 1.2% vs 15.5%

p-value: p=<0.01

Abstract

BACKGROUND: Defining the presence, extent, and nature of the dysfunctional myocardial tissue remains a cornerstone in diagnostic cardiology. A nonfluoroscopic, catheter-based mapping technique that can spatially associate endocardial mechanical and electrical data was used to quantify electromechanical changes in the canine chronic infarction model. METHODS AND RESULTS: We mapped the left ventricular (LV) electromechanical regional properties in 11 dogs with chronic infarction (4 weeks after LAD ligation) and 6 controls. By sampling the location of a special catheter throughout the cardiac cycle at multiple endocardial sites and simultaneously recording local electrograms from the catheter tip, the dynamic 3-dimensional electromechanical map of the LV was reconstructed. Average endocardial local shortening (LS, measured at end systole and normalized to end diastole) and intracardiac bipolar electrogram amplitude were quantified at 13 LV regions. Endocardial LS was significantly lower at the infarcted area (1.2+/-0.9% mean+/-SEM, P<0.01) compared with the noninfarcted regions (7.2+/-1.1% to 13. 5+/-1.5%) and with the same area in controls (15.5+/-1.2%, P<0.01). Average bipolar amplitude was also significantly lower at the infarcted zone (2.3+/-0.2 mV, P<0.01) compared with the same region in controls (10.3+/-1.3 mV) and with the noninfarcted regions (4. 0+/-0.7 to 10.2+/-1.5 mV, P<0.01) in the infarcted group. In addition, the electrical maps could accurately delineate both the location and extent of the infarct, as demonstrated by the high correlation with pathology (Pearson's correlation coefficient=0.90) and by the precise identification of the infarct border. CONCLUSIONS: Chronic myocardial infarcted tissue can be characterized and quantified by abnormal regional mechanical and electrical functions. The unique ability to assess the regional ventricular electromechanical properties in various myocardial disease states may become a powerful tool in both clinical and research cardiology.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Gepstein et al. (1998) studied Chronic Myocardial Infarction (n=17). Nonfluoroscopic, catheter-based electromechanical mapping vs. Controls was evaluated on Endocardial local shortening (LS) (p=<0.01). Catheter-based electromechanical mapping demonstrated significantly lower endocardial local shortening in infarcted areas compared to controls (1.2% vs 15.5%, P<0.01).

synapsesocial.com/papers/6a0f61608090e499da5fbbebhttps://doi.org/10.1161/01.cir.98.19.2055
Ask AI
Helpful
Bookmark
Share
View Full Paper