PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
March 14, 2013Journal of Mechanics in Medicine and Biology94 citations

Detection of Human Stress Using Short-Term Ecg and HRV Signals

View Full Paper
PKP. KarthikeyanMMM. MurugappanSYSazali Yaacob

Structured PICO

Does a methodology using short-term ECG and HRV signals accurately detect human stress?

P
Population
60 subjects (30 males and 30 females) participating in a Stroop color word-based stress-inducing task
I
Intervention
Stress detection methodology using short-term (<5 min) ECG and HRV signals processed with wavelet denoising, Lomb-Scargle periodogram, and PNN/kNN classifiers
C
Comparator
Normal state (baseline)
O
Outcome
Classification accuracy of normal vs stress statessurrogate

Short-term ECG and HRV signals can be used to detect human stress with high accuracy using advanced signal processing and machine learning classifiers.

Abstract

This paper introduces a method for resolving the problem of human stress detection through short-term (less than 5 min) electrocardiogram (ECG) and heart rate variability (HRV) signals. The explored methodology helps to improve the stress detection rate and reliability through multiple evidences originated in same sensor. In this work, stress-inducing protocol, data acquisition, preprocessing, feature extraction and classification are the major steps involved to detect the stress. In total, 60 subjects (30 males and 30 females) participated in the Stroop color word-based stress-inducing task and ECG signal was acquired simultaneously. The wavelet denoising algorithm was applied to remove high frequency, baseline wander and power line noises. Discrete wavelet transform (DWT)-based heart rate (HR) detection algorithm is used for deriving HRV signal from the preprocessed ECG signal. The ectopic beat removal method is employed to eliminate the ectopic beat and noise peaks in the HRV signal. In order to detect the stress, the issue of uneven sampling with the HRV signal has been successfully rectified using the Lomb-Scargle periodogram (LSP). The application of LSP in short-term HRV signals (32 s), uneven sampling issue, and power spectral information issue has been rectified and the trustworthiness of the short-term HRV signal has been proved by hypothesis as well as experimental results. Theoretical analysis suggested that a minimum 25 s of online or offline ECG data is required to analyze the autonomous nervous system (ANS) activity related to stress. In addition to the HRV signal, ECG-based stress assessment has been proposed to detect the stress through optimum features using fast Fourier transform (FFT). Various features extracted from the ECG and HRV signal have been classified into normal and stress using PNN and kNN classifiers with different smoothing factor and k values. The experimental results indicate that the proposed methodology for short-term ECG and HRV signal can achieve the overall average classification accuracy of 91.66% and 94.66% in the subject-independent mode.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Karthikeyan et al. (2013) studied this question.

synapsesocial.com/papers/6a0f9dc4d03631df9ce9ccc7https://doi.org/10.1142/s0219519413500383
Ask AI
Helpful
Bookmark
Share
View Full Paper