September 1, 1990Psychophysiology399 citations

An Approach to Artifact Identification: Application to Heart Period Data

View Full Paper
GBGary G. BerntsonKQKaren S. QuigleyJJJaye F. Jang

Key Points

  • To develop and evaluate an automated, distribution-based strategy for identifying artifacts in heart period data.
  • Designed an algorithm using individual subject distributions of successive heart period differences, relying on percentile-based indexes rather than least-squares estimates.
  • Evaluated the algorithm's performance on datasets derived from humans and chimpanzees containing 1,494 simulated and actual artifacts.
  • The algorithm successfully identified 100% of the 1,494 simulated and actual artifactual beats embedded in heart period records.
  • The detection framework achieved a false alarm rate of less than 0.3%.

Abstract

A rational strategy for the automated detection of artifacts in heart period data is outlined and evaluated. The specific implementation of this approach for heart period data is based on the distribution characteristics of successive heart period differences. Because beat-to-beat differences generated by artifacts are large, relative to normal heart period variability, extreme differences between successive heart periods serve to identify potential artifacts. Critical to this approach are: 1) the derivation of the artifact criterion from the distribution of beat differences of the individual subject, and 2) the use of percentile-based distribution indexes, which are less sensitive to corruption by the presence of artifactual values than are least-squares estimates. The artifact algorithms were able to effectively identify artifactual beats embedded in heart period records, flagging each of the 1494 simulated and actual artifacts in data sets derived from both humans and chimpanzees. At the same time, the artifact algorithms yielded a false alarm rate of less than 0.3%. Although the present implementation was restricted to heart period data, the outlined approach to artifact detection may also be applicable to other biological signals.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Berntson et al. (1990) studied this question.