PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
January 1, 2005Thrombosis and Haemostasis145 citations

D-dimer, P-selectin, and microparticles: Novel markers to predict deep venous thrombosis

DMDaniel D. MyersAHAngela E. HawleyCLChristopher R. Longo

Key Result

No clinical study data is present in the provided text, which consists only of journal editorial board information.

Structured PICO

Do combined plasma assays for D-dimer, soluble P-selectin, and total microparticles accurately diagnose deep venous thrombosis in symptomatic patients?

P
Population
73 individuals divided into 3 groups: 30 normal controls (Group 1), 22 patients positive for deep venous thrombosis (DVT) on duplex ultrasound (Group 2), and 21 symptomatic patients negative for DVT on duplex ultrasound (Group 3).
I
Intervention
Plasma assays for D-dimer, soluble P-selectin, and total microparticles
C
Comparator
Comparison between DVT-positive patients, symptomatic DVT-negative patients, and normal controls
O
Outcome
Sensitivity, specificity, and accuracy of combined plasma markers to differentiate DVT-positive from symptomatic DVT-negative patientssurrogate

Combining D-dimer, soluble P-selectin, and total microparticles provides moderate diagnostic accuracy for DVT, highlighting the potential role of P-selectin, though further improvements are needed for clinical application.

Abstract

Current plasma markers for diagnosis of deep venous thrombosis (DVT) allow for exclusion of the diagnosis, but lack adequate specificity to establish the diagnosis. Thus, a prospective study was performed to determine the sensitivity and specificity of plasma assays for D-dimer, soluble P-selectin (P-selectin), and total microparticles in patients with documented DVT by duplex ultrasound. Three groups of individuals were examined: 30 normals; 22 positive for DVT on duplex ultrasound (Group 2); and 21 symptomatic, but negative on duplex ultrasound for DVT (Group 3). Group 1 individuals had D-dimer values of 1.53 +/- 0.12 mg/l and P-selectin values of 0.34 +/- 0.05 ng/mg total protein. Group 2 vs. Group 3 individuals had D-dimer values of 7.57 +/- 2.03 vs. 3.19 +/- 0.79 mg/l, p = 0.02; P-selectin values of 0.98 +/- 0.11 vs. 0.55 +/- 0.08 ng/mg total protein, p < 0.01; and micro-particle values of 129 +/- 17% vs. 99 +/- 12% of control, p = ns. Using a logistic regression model with dichotomous variables, we determined a sensitivity of 73%, specificity of 81%, and accuracy of 77% when combining D-dimer, soluble P-selectin, and total microparticles to differentiate Group 2 from Group 3 patients. Logistic regression using continuous variables yielded similar results (p = 0.05). This study demonstrates that plasma markers for DVT can be developed and achieve moderate sensitivity and specificity in diagnosing DVT. However for clinical applicability, the sensitivity/specificity will need to be improved. These studies also suggest the importance of soluble P-selectin in assessing DVT in humans.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Myers et al. (2005) studied this question. No clinical study data is present in the provided text, which consists only of journal editorial board information.

synapsesocial.com/papers/6a12bec586514ddae6c078b8https://doi.org/10.1160/th05-06-0426
Ask AI
Helpful
Bookmark
Share
View Full Paper