November 14, 2022Frontiers in Cardiovascular Medicine7 citationsOpen Access

Risk factors and clinical effects of subclinical leaflet thrombosis after transcatheter aortic valve replacement

MBMinjung BakSPSung‐Ji ParkKCKi-Hong Choi

Key Result

Aortic valve calcium volume over 423.5 mm3 was independently associated with a significantly increased risk of subclinical leaflet thrombosis after transcatheter aortic valve replacement (OR 5.040).

Study Design

Type

Observational (n=94)

Multicenter

No

Structured PICO

What are the risk factors for subclinical leaflet thrombosis after TAVR, and does it affect hemodynamics or clinical outcomes?

P
Population
94 patients who underwent transcatheter aortic valve replacement (TAVR) and had multidetector computed tomography (MDCT) at 1 year follow-up at a single center in South Korea.
I
Intervention
Subclinical leaflet thrombosis (identified on MDCT at 1 year)
C
Comparator
No subclinical leaflet thrombosis
O
Outcome
Risk factors for subclinical leaflet thrombosis, aortic valve hemodynamics, and clinical outcomessurrogate

Subclinical leaflet thrombosis after TAVR is associated with specific anatomical and procedural factors (larger SOV diameter, higher AV calcium, smaller post-procedure EOA) and alters valve hemodynamics, but appears to have a benign clinical course when properly managed.

Main Result

Effect estimate: OR 5.040 (95% CI 1.395-18.213)

p-value: p=0.014

Limitations

  • Small number of patients made it difficult to perform enough sub-analyses
  • Most patients who had follow-up CT did not have chronic kidney disease due to concerns regarding contrast nephrotoxicity
  • Diversity of patients was limited because subjects were recruited from a single center and were predominantly Asian

Abstract

Aims The number of trans-catheter aortic valve replacement (TAVR) procedure is increasing; However, the incidence of leaflet thrombosis is higher in TAVR than in surgical aortic valve replacement (SAVR). In this study, the risk factors for leaflet thrombosis after TAVR and its effects on hemodynamics and clinical course were investigated. Methods and results Multidetector computed tomography (MDCT) was performed at 1year after TAVR in 94 patients from January 2015 to October 2020 at Samsung Medical Center in South Korea. Among the 94 patients, subclinical leaflet thrombosis occurred in 20 patients, and risk factors were analyzed. In addition, the difference in aortic valve (AV) hemodynamics between the two groups was examined and clinical outcomes compared. Indexed mean sinus of Valsalva (SOV) diameter, AV calcium volume, and post-procedure effective orifice area (EOA) were predictive of subclinical leaflet thrombosis with the area under the curve (AUC) value of 0.670 ( P -value = 0.020), 0.695 ( P -value = 0.013), and 0.665 ( P -value = 0.031), respectively. In echocardiography performed at the time of follow-up CT, the value of AV max velocity and AV mean pressure gradient were higher in the thrombosis group and the EOA and Doppler velocity index values were lower in the thrombosis group than in the no thrombosis group. Clinical outcome was not significantly different between the two groups (log-rank P -value = 0.26). Conclusion Larger indexed SOV diameter, higher AV calcium volume, and smaller post-procedure AV EOA were risk factors for subclinical leaflet thrombosis after TAVR. Subclinical leaflet thrombosis has a benign course when properly managed.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Bak et al. (2022) conducted an observational in Aortic stenosis post-transcatheter aortic valve replacement (TAVR) (n=94). Aortic valve calcium volume > 423.5 mm3 vs. Aortic valve calcium volume ≤ 423.5 mm3 was evaluated on Subclinical leaflet thrombosis (OR 5.040, 95% CI 1.395-18.213, p=0.014). Aortic valve calcium volume over 423.5 mm3 was independently associated with a significantly increased risk of subclinical leaflet thrombosis after transcatheter aortic valve replacement (OR 5.040).

synapsesocial.com/papers/6a13f48e2ecb6dc5418938eahttps://doi.org/10.3389/fcvm.2022.1001753
Ask AI
Helpful
Bookmark
Share
View Full Paper